Artículo
Optimization and Validation of a UV-HPLC Method for Vitamin C Determination in Strawberries (Fragaria ananassa Duch.), Using Experimental Designs
Van de Velde, Franco
; Pirovani, Maria Elida; Cámara, María Silvia; Güemes, Daniel Raul; Bernardi, Cecilia María del Huerto
Fecha de publicación:
09/2012
Editorial:
Springer
Revista:
Food Analytical Methods
ISSN:
1936-9751
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
Vitamin C or total ascorbic acid (TAA) in fruits can be assumed as ascorbic acid (AA) plus dehydroascorbic acid (DHA) content. The aim of this work was to optimize and validate, using experimental designs, a new high-performance liquid chromatographic method for vitamin C determination in strawberries. The mobile phase (MP) consisted of a 0. 03 M sodium acetate/acetic acid buffer, 5% methanol. For optimization, a Box-Behnken design was used (three factors at three levels: (a) pH of MP, 3. 8-5. 8; (b) wavelength, 240-270 nm; and (c) flow rate, 0. 5-1. 2 ml min -1). Responses were: AA and TAA areas, peak widths, and retention times. A global optimization was performed using the Derringer desirability function, and a value of 0. 84 was reached for the combination of design factors: A = 5. 8, B = 251 nm, and C = 1. 15 ml min -1. Method validation, using AA standard solutions, included: linearity study, limits of detection and quantification, and calibration and analytical sensitivity quantifications. Precision and accuracy were studied in strawberry extracts. The coefficients of variation (percent) were: AA, 1. 5%; TAA, 1. 8%, and DHA, 4. 9%. Accuracy was evaluated with AA standard spiked in 30-150% range of the expected amount of analyte in real samples. The joint confidence elliptical region test and t test were employed for the study of the difference between recoveries (percent) and the ideal 100%. The robustness was analyzed using a fractional factorial design (3 4-2), and an AA recovery study after slight changes in operative variables was performed. The results indicate that the optimized method was linear, sensible, precise, accurate, and robust.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(CCT - SANTA FE)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - SANTA FE
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - SANTA FE
Citación
Van de Velde, Franco; Pirovani, Maria Elida; Cámara, María Silvia; Güemes, Daniel Raul; Bernardi, Cecilia María del Huerto; Optimization and Validation of a UV-HPLC Method for Vitamin C Determination in Strawberries (Fragaria ananassa Duch.), Using Experimental Designs; Springer; Food Analytical Methods; 5; 5; 9-2012; 1097-1104
Compartir
Altmétricas