Monochromatic image reconstruction by dual energy imaging allows half iodine load computed tomography coronary angiography

Carrascosa, Patricia ; Leipsic, Jonathon A. ; Capunay, Carlos ; Deviggiano, Alejandro ; Vallejos, Javier ; Goldsmit, Alejandro ; Rodriguez Granillo, Gaston Alfredo Icon

Otros responsables

Fecha

10/2015

Editorial

Elsevier Ireland

Revista

European Journal Of Radiology

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0720-048X

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

Purpose: To compare image interpretability and diagnostic performance of dual-energy CT coronary angiography (DE-CTCA) performed with 50% iodine load reduction versus single energy acquisitions (SE-CTCA) with full iodine load. Materials and methods: The present prospective study involved patients with suspected coronary artery disease (CAD) clinically referred for CTCA. DE-CTCA with 50% iodine volume load was performed first, and after heart rate returned to baseline SE-CTCA was performed using full iodine volume load. The primary endpoint was to compare image interpretability between groups. DE-CTCA was performed by rapid switching between low and high tube potentials (80–140 kV) from a single source, allowing the generation of monochromatic image reconstructions ranging from 40 to 140 keV. Image quality assessment was performed using a 5-point Likert scale. Results: Thirty-six patients constituted the study population. The mean heart rate before the CT scan (DE-CTCA 57.3 ± 10.7 bpm vs. SE-CTCA 58.5 ± 11.2 bpm, p = 0.29) and the mean effective radiation dose (3.5 ± 1.9 mSv vs. 3.8 ± 0.9 mSv, p = 0.48) did not differ between groups. Likert image quality scores were similar between groups (DE-CTCA 4.42 ± 0.98 vs. SE-CTCA 4.43 ± 0.84, p = 0.67). Signal-to-noise and contrast-to-noise ratios were significantly lower with DE-CTCA, driven by lower signal density levels at 60 keV compared to SE-CTCA. The sensitivity and specificity for the detection of stenosis >50% was indistinguishable between groups (DE-CTCA 84.4% (69.9–93.0%), 87.1% (81.6–91.2%); SE-CTCA 84.4% (69.9–93.0%), 87.1% (81.6–91.2%). Conclusions: In this pilot, prospective study, dual energy CTCA imaging with half iodine load achieved comparable interpretability than full iodine load with single energy CTCA.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd