Evaluación del funcionamiento de un sistema fv de 2,8 kw con sombreado parcial
; J.C. Durán Otros responsables
Fecha
09/2014
Editorial
Asociación Argentina de Energías Renovables y Ambiente
Revista
Avances en Energías Renovables y Medio Ambiente
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
2314-1433
eISSN
ISBN
Idioma
Español
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Se analiza el funcionamiento de un sistema fotovoltaico, compuesto por 12 paneles solares de 240 Wp conectados en serie y un inversor de 2,8 kW, sometido a la presencia de sombras parciales producidas por una baranda. Se presentan curvas corriente-tensión de un módulo fotovoltaico y de los 12 módulos conectados en serie, y se estima la pérdida de energía generada para días despejados dentro del período marzo-junio de 2014. El análisis se realizó a partir de mediciones de perfiles de generación obtenidos mediante un analizador/registrador de red. Las estimaciones arrojan valores de pérdidas diarias que superan el 10% para días despejados cercanos al solsticio de invierno, siendo significativamente menores en abril para finalmente ser despreciables (< 1%) en fechas próximas a los equinoccios.
The operation of a photovoltaic system, consisting of 12 240 Wp photovoltaic modules connected in series and a 2.8 kW inverter, subject to the presence of partial shadows produced by a railing is analyzed. Current-voltage curves of a photovoltaic module and 12 modules connected in series are presented and the energy loss for clear days in the period from March to June 2014 is estimated. The analysis was performed using measurements obtained by a power monitoring instrument. The estimated daily energy losses exceed 10% for clear days near the winter solstice, being significantly lower in April and negligible (<1%) in days close to the equinox.
The operation of a photovoltaic system, consisting of 12 240 Wp photovoltaic modules connected in series and a 2.8 kW inverter, subject to the presence of partial shadows produced by a railing is analyzed. Current-voltage curves of a photovoltaic module and 12 modules connected in series are presented and the energy loss for clear days in the period from March to June 2014 is estimated. The analysis was performed using measurements obtained by a power monitoring instrument. The estimated daily energy losses exceed 10% for clear days near the winter solstice, being significantly lower in April and negligible (<1%) in days close to the equinox.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa