Reducing risks in type 1 diabetes using H∞ Control
; Sanchez Peña, Ricardo Salvador
; Gondhalekar, Ravi ; Dassau, Eyal ; Doyle, Francis J. Otros responsables
Fecha
12/2014
Editorial
Institute of Electrical and Electronics Engineers
Revista
Ieee Transactions On Bio-medical Engineering
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0018-9294
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
A control scheme was designed in order to reduce the risks of hyperglycemia and hypoglycemia in type 1 diabetes mellitus (T1DM). This structure is composed of three main components: an H∞ robust controller, an insulin feedback loop (IFL), and a safety mechanism (SM). A control-relevant model that is employed to design the robust controller is identified. The identification procedure is based on the distribution version of the UVA/Padova metabolic simulator using the simulation adult cohort. The SM prevents dangerous scenarios by acting upon a prediction of future glucose levels, and the IFL modifies the loop gain in order to reduce postprandial hypoglycemia risks. The procedure is tested on the complete in silico adult cohort of the UVA/Padova metabolic simulator, which has been accepted by the Food and Drug Administration (FDA) in lieu of animal trials.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa