Direct measurement and modeling of intraglottal, subglottal, and vocal fold collision pressures during phonation in an individual with a hemilaryngectomy | ||
| dc.conicet.fuente | individual | |
| dc.conicet.organizacion | Massachusetts General Hospital | |
| dc.conicet.organizacion | Massachusetts General Hospital | |
| dc.conicet.organizacion | Harvard Medical School. Department of Medicine. Massachusetts General Hospital | |
| dc.conicet.organizacion | Universidad Técnica Federico Santa María | |
| dc.conicet.organizacion | Universidad Técnica Federico Santa María | |
| dc.conicet.organizacion | Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática | |
| dc.conicet.organizacion | Universidad Técnica Federico Santa María | |
| dc.conicet.organizacion | Clarkson University | |
| dc.conicet.organizacion | University of Waterloo | |
| dc.conicet.organizacion | Center For Laryngeal Surgery and Voice Rehabilitation | |
| dc.conicet.organizacion | Center For Laryngeal Surgery and Voice Rehabilitation | |
| dc.conicet.organizacion | Harvard Medical School. Department of Medicine. Massachusetts General Hospital | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Chile | |
| dc.conicet.paisOrganizacion | Chile | |
| dc.conicet.paisOrganizacion | Argentina | |
| dc.conicet.paisOrganizacion | Chile | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Canadá | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.produccionid | 9742436 | |
| dc.contributor.author | Mehta, Daryush D. | |
| dc.contributor.author | Kobler, James B. | |
| dc.contributor.author | Zeitels, Steven M. | |
| dc.contributor.author | Zañartu, Matías | |
| dc.contributor.author | Ibarra, Emiro J. | |
| dc.contributor.author | Alzamendi, Gabriel Alejandro | |
| dc.contributor.author | Manriquez, Rodrigo | |
| dc.contributor.author | Erath, Byron D. | |
| dc.contributor.author | Peterson, Sean D. | |
| dc.contributor.author | Petrillo, Robert H. | |
| dc.contributor.author | Hillman, Robert E. | |
| dc.date.accessioned | 2022-10-17T12:45:24Z | |
| dc.date.available | 2022-10-17T12:45:24Z | |
| dc.date.issued | 2021-08 | |
| dc.date.updated | 2022-09-14T14:12:19Z | |
| dc.description.abstract | The purpose of this paper is to report on the first in vivo application of a recently developed transoral, dual-sensor pressure probe that directly measures intraglottal, subglottal, and vocal fold collision pressures during phonation. Synchronous measurement of intraglottal and subglottal pressures was accomplished using two miniature pressure sensors mounted on the end of the probe and inserted transorally in a 78-year-old male who had previously undergone surgical removal of his right vocal fold for treatment of laryngeal cancer. The endoscopist used one hand to position the custom probe against the surgically medialized scar band that replaced the right vocal fold and used the other hand to position a transoral endoscope to record laryngeal high-speed videoendoscopy of the vibrating left vocal fold contacting the pressure probe. Visualization of the larynx during sustained phonation allowed the endoscopist to place the dual-sensor pressure probe such that the proximal sensor was positioned intraglottally and the distal sensor subglottally. The proximal pressure sensor was verified to be in the strike zone of vocal fold collision during phonation when the intraglottal pressure signal exhibited three characteristics: an impulsive peak at the start of the closed phase, a rounded peak during the open phase, and a minimum value around zero immediately preceding the impulsive peak of the subsequent phonatory cycle. Numerical voice production modeling was applied to validate model-based predictions of vocal fold collision pressure using kinematic vocal fold measures. The results successfully demonstrated feasibility of in vivo measurement of vocal fold collision pressure in an individual with a hemilaryngectomy, motivating ongoing data collection that is designed to aid in the development of vocal dose measures that incorporate vocal fold impact collision and stresses. | es |
| dc.description.fil | Fil: Mehta, Daryush D.. Massachusetts General Hospital; Estados Unidos | |
| dc.description.fil | Fil: Kobler, James B.. Massachusetts General Hospital; Estados Unidos | |
| dc.description.fil | Fil: Zeitels, Steven M.. Harvard Medical School. Department of Medicine. Massachusetts General Hospital; Estados Unidos | |
| dc.description.fil | Fil: Zañartu, Matías. Universidad Técnica Federico Santa María; Chile | |
| dc.description.fil | Fil: Ibarra, Emiro J.. Universidad Técnica Federico Santa María; Chile | |
| dc.description.fil | Fil: Alzamendi, Gabriel Alejandro. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina | |
| dc.description.fil | Fil: Manriquez, Rodrigo. Universidad Técnica Federico Santa María; Chile | |
| dc.description.fil | Fil: Erath, Byron D.. Clarkson University; Estados Unidos | |
| dc.description.fil | Fil: Peterson, Sean D.. University of Waterloo; Canadá | |
| dc.description.fil | Fil: Petrillo, Robert H.. Center For Laryngeal Surgery and Voice Rehabilitation; Estados Unidos | |
| dc.description.fil | Fil: Hillman, Robert E.. Center For Laryngeal Surgery and Voice Rehabilitation; Estados Unidos. Harvard Medical School. Department of Medicine. Massachusetts General Hospital; Estados Unidos | |
| dc.format | application/pdf | es |
| dc.identifier.citation | Mehta, Daryush D.; Kobler, James B.; Zeitels, Steven M.; Zañartu, Matías; Ibarra, Emiro J.; et al.; Direct measurement and modeling of intraglottal, subglottal, and vocal fold collision pressures during phonation in an individual with a hemilaryngectomy; MDPI AG; Applied Sciences; 11; 16; 8-2021; 1-18 | es |
| dc.identifier.institucional | CONICET | |
| dc.identifier.issn | 2076-3417 | es |
| dc.identifier.repo | CONICET Digital | |
| dc.identifier.uri | http://hdl.handle.net/11336/173432 | |
| dc.journal.ciudad | Basel | es |
| dc.journal.number | 16 | es |
| dc.journal.pagination | 1-18 | es |
| dc.journal.pais | Suiza | es |
| dc.journal.title | Applied Sciences | es |
| dc.journal.volume | 11 | es |
| dc.language.iso | eng | es |
| dc.publisher | MDPI AG | es |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/url/https://www.mdpi.com/2076-3417/11/16/7256 | |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.3390/app11167256 | |
| dc.rights | info:eu-repo/semantics/openAccess | * |
| dc.rights.uri | https://creativecommons.org/licenses/by/2.5/ar/ | * |
| dc.subject | HEMILARYNGECTOMY | es |
| dc.subject | INTRAGLOTTAL PRESSURE | es |
| dc.subject | SUBGLOTTAL PRESSURE | es |
| dc.subject | VOCAL FOLD COLLISION | es |
| dc.subject.classification | Otras Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información | es |
| dc.subject.classification | Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información | es |
| dc.subject.classification | INGENIERÍAS Y TECNOLOGÍAS | es |
| dc.title | Direct measurement and modeling of intraglottal, subglottal, and vocal fold collision pressures during phonation in an individual with a hemilaryngectomy | es |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:ar-repo/semantics/artículo | |
| dc.type | info:eu-repo/semantics/publishedVersion | |
Archivos
Bloque original
Cargando...
- Nombre:
- CONICET_Digital_Nro.f3b327cf-b23f-42ef-a490-d5247c99f489_B.pdf
- Tamaño:
- 3.22 MB
- Formato:
- Adobe Portable Document Format