Reversible focal intracranial hypertension swine model with continuous multimodal neuromonitoring
; Saez, Pablo ; Garcia, Maria del Carman ; Padilla, Fernando ; Plou, Pedro ; Hem, Santiago ; Karippacheril, John George ; Figar Gutiérrez, Alejandro ; Redelico, Francisco Oscar 
Otros responsables
Fecha
05/2022
Editorial
Elsevier Science
Revista
Journal of Neuroscience Methods
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0165-0270
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Background: Intracranial hypertension (HI) is associated with worse neurological outcomes and higher mortality. Although there are several experimental models of HI, in this article we present a reproducible, reversible, and reliable model of intracranial hypertension, with continuous multimodal monitoring. New method: A reversible intracranial hypertension model in swine with multimodal monitoring including intracranial pressure, arterial blood pressure, heart rate variation, brain tissue oxygenation, and electroencephalogram is developed to understand the relationship of ICP and EEG. By inflating and deflating a balloon, located 20 mm anterior to the coronal suture and a 15 mm sagittal suture, we generate intracranial hypertension events and simultaneously measure intracranial pressure and oxygenation in the contralateral hemisphere and the EEG, simulating the usual configuration in humans. Results: We completed 5 experiments and in all of them, we were able to complete at least 6 events of intracranial hypertension in a stable and safe way. For events of 20–40 mmHg of ICP we need an median (IQR) of 4.2 (3.64) ml of saline solution into the Foley balloon, a median (IQR) infusion time of 226 (185) second in each event and for events of 40–50 mmHg of ICP we need a median (IQR) of 5.1 (4.66) ml of saline solution, a median (IQR) infusion time of 280 (48) seconds and a median (IQR). The median (IQR) maintenance time was 352 (77) seconds and 392 (166) seconds for 20–40 mmHg and 40–50 mmHg of ICP, respectively. Comparison with existing method(s): Existing methods do not include EEG measures and do not present the reversibility of intracranial hypertension. Conclusions: Our model is fully reproducible, it is capable of generating reversible focal intracranial hypertension through strict control of the injected volume, it is possible to generate different infusion rates of the volume in the balloon, in order to generate different scenarios, the data obtained are sufficient to determine the brain complacency in real time. and useful for understanding the pathophysiology of ICP and the relationship between ICP (CPP) and EEG.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa