The drop plate method as an alternative for Azospirillum spp viable cell enumeration within the consensus protocol of the REDCAI network
; García, Julia E. ; Puente, Mariana Laura ; Amigo, Josefina Alejandra ; Anriquez, Analia Liliana ; Barlocco, Claudia ; Benintende, Silvia Mercedes ; Bochatay, Tatiana ; Bortolato, Marta Alejandra ; Cassan, Fabricio Dario
; Ramirez Castaño, Carolina ; Catafesta, Melina ; Coniglio, Nayla Anahí
; Díaz, Marisa ; Galian, Liliana Rosa ; Gallace, María Eugenia
; Garcia, Patricia Graciela
; García de Salamone, Inés E. ; Landa, Marianela ; Liernur, Germán ; Maneiro, María Laura ; Massa, Rosana ; Malinverni, Julieta ; Marchessi, Nicolas Carlos ; Monteleone, Emilia ; Oviedo, Silvina ; Pobliti, Lucrecia ; Portela, Gabriela Rut ; Radovancich, Débora ; Righes, Silvia Otros responsables
Fecha
2021-07-07
Editorial
Asociación Argentina de Microbiología
Revista
Revista Argentina de Microbiología
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0325-7541
eISSN
1851-7617
ISBN
Idioma
Español
Tipo del evento
Clasificación temática
Palabras clave
Resumen
La evaluación de la calidad de los inoculantes comerciales es fundamental para garantizar una adecuada respuesta de los cultivos a la inoculación dentro de un marco de bioseguridad. En este sentido, el objetivo de este trabajo fue la estandarización y validación de la técnica de la microgota para la cuantificación de Azospirillum como metodología alternativa a la técnica de siembra en superficie, propuesta actualmente en el protocolo consenso de la Red de Calidad de Inoculantes, REDCAI. Entre 14 y 25 laboratorios, tanto privados como públicos, participaron de tres ensayos independientes. A partir de ellos se obtuvieron resultados reproducibles y robustos que permiten confirmar que ambas técnicas son equivalentes y concluir que la técnica de recuento por la microgota es una alternativa adecuada para ser incluida dentro del mencionado protocolo consenso.
Quality evaluation of commercial inoculants is essential to warrant an adequate crop response to inoculation within a biosecurity framework. In this sense, this work is aimed at standardizing and validating the drop plate method for the enumeration of Azospirillum viable cells as an alternative to the spread plate technique, which is currently proposed in the consensus protocol of the REDCAI network. Between 14 and 25 private and public laboratories participated in three independent trials. We obtained consistent and robust results that allowed to confirm that both techniques are equivalent, concluding that the drop plate method is an alternative enumeration technique that is adequate to be included in the abovementioned consensus protocol.
Quality evaluation of commercial inoculants is essential to warrant an adequate crop response to inoculation within a biosecurity framework. In this sense, this work is aimed at standardizing and validating the drop plate method for the enumeration of Azospirillum viable cells as an alternative to the spread plate technique, which is currently proposed in the consensus protocol of the REDCAI network. Between 14 and 25 private and public laboratories participated in three independent trials. We obtained consistent and robust results that allowed to confirm that both techniques are equivalent, concluding that the drop plate method is an alternative enumeration technique that is adequate to be included in the abovementioned consensus protocol.