Combined molecular MRI and immuno-spin trapping for in vivo detection of free radicals in orthotopic mouse GL261 glioma | ||
| dc.conicet.organizacion | Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center | |
| dc.conicet.organizacion | Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center | |
| dc.conicet.organizacion | Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center | |
| dc.conicet.organizacion | Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center | |
| dc.conicet.organizacion | Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center | |
| dc.conicet.organizacion | Oklahoma Medical Research Foundation | |
| dc.conicet.organizacion | Oklahoma Medical Research Foundation | |
| dc.conicet.organizacion | National Institute of Environmental Health Sciences. Laboratory of Toxicology and Pharmacology | |
| dc.conicet.organizacion | National Institute of Environmental Health Sciences. Laboratory of Toxicology and Pharmacology | |
| dc.conicet.organizacion | Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto Multidisciplinario de Investigaciones Biológicas de San Luis | |
| dc.conicet.organizacion | Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto Multidisciplinario de Investigaciones Biológicas de San Luis | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Estados Unidos | |
| dc.conicet.paisOrganizacion | Argentina | |
| dc.conicet.paisOrganizacion | Argentina | |
| dc.conicet.produccionid | 2788536 | |
| dc.contributor.author | Towner, Rheal A. | |
| dc.contributor.author | Smith, Nataliya | |
| dc.contributor.author | Saunders, Debra | |
| dc.contributor.author | Coutinho, Patricia De Souza | |
| dc.contributor.author | Henry, Leah | |
| dc.contributor.author | Lupu, Florea | |
| dc.contributor.author | Silasi Mansat, Robert | |
| dc.contributor.author | Ehernshaft, Marilyn | |
| dc.contributor.author | Mason, Ronald P. | |
| dc.contributor.author | Gomez-Mejiba, Sandra Esther | |
| dc.contributor.author | Ramirez, Dario | |
| dc.date.accessioned | 2016-02-22T19:43:31Z | |
| dc.date.available | 2016-02-22T19:43:31Z | |
| dc.date.issued | 2013-12 | |
| dc.date.updated | 2016-03-30 10:35:44.97925-03 | |
| dc.description.abstract | Free radicals play a major role in gliomas. By combining immuno-spin-trapping (IST) and molecular magnetic resonance imaging (mMRI), in vivo levels of free radicals were detected within mice bearing orthotopic GL261 gliomas. The nitrone spin trap DMPO (5,5-dimethyl pyrroline N-oxide) was administered prior to injection of an anti-DMPO probe (anti-DMPO antibody covalently bound to a bovine serum albumin (BSA)–Gd (gadolinium)-DTPA (diethylene triamine penta acetic acid)–biotin MRI contrast agent) to trap tumor-associated free radicals. mMRI detected the presence of anti-DMPO adducts by either a significant sustained increase (p < 0.001) in MR signal intensity or a significant decrease (p < 0.001) in T1 relaxation, measured as %T1 change. In vitro assessment of the anti-DMPO probe indicated a significant decrease (p < 0.0001) in T1 relaxation in GL261 cells that were oxidatively stressed with hydrogen peroxide, compared to controls. The biotin moiety of the anti-DMPO probe was targeted with fluorescently-labeled streptavidin to locate the anti-DMPO probe in excised brain tissues. As a negative control a non-specific IgG antibody covalently bound to the albumin–Gd-DTPA–biotin construct was used. DMPO adducts were also confirmed in tumor tissue from animals administered DMPO, compared to non-tumor brain tissue. GL261 gliomas were found to have significantly increased malondialdehyde (MDA) protein adducts (p < 0.001) and 3-nitrotyrosine (3-NT) (p < 0.05) compared to normal mouse brain tissue, indicating increased oxidized lipids and proteins, respectively. Co-localization of the anti-DMPO probe with either 3-NT or 4-hydroxynonenal was also observed. This is the first report regarding the detection of in vivo levels of free radicals from a glioma model. | es |
| dc.description.fil | Fil: Towner, Rheal A.. Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center; Estados Unidos | |
| dc.description.fil | Fil: Smith, Nataliya. Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center; Estados Unidos | |
| dc.description.fil | Fil: Saunders, Debra. Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center; Estados Unidos | |
| dc.description.fil | Fil: Coutinho, Patricia De Souza. Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center; Estados Unidos | |
| dc.description.fil | Fil: Henry, Leah. Oklahoma Health Sciences Center. Advanced Magnetic Resonance Center; Estados Unidos | |
| dc.description.fil | Fil: Lupu, Florea. Oklahoma Medical Research Foundation; Estados Unidos | |
| dc.description.fil | Fil: Silasi Mansat, Robert. Oklahoma Medical Research Foundation; Estados Unidos | |
| dc.description.fil | Fil: Ehernshaft, Marilyn. National Institute of Environmental Health Sciences. Laboratory of Toxicology and Pharmacology; Estados Unidos | |
| dc.description.fil | Fil: Mason, Ronald P.. National Institute of Environmental Health Sciences. Laboratory of Toxicology and Pharmacology ; Estados Unidos | |
| dc.description.fil | Fil: Gomez-Mejiba, Sandra Esther. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto Multidisciplinario de Investigaciones Biológicas de San Luis; Argentina | |
| dc.description.fil | Fil: Ramirez, Dario. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto Multidisciplinario de Investigaciones Biológicas de San Luis; Argentina | |
| dc.format | application/pdf | es |
| dc.identifier.citation | Towner, Rheal A.; Smith, Nataliya; Saunders, Debra; Coutinho, Patricia De Souza; Henry, Leah; et al.; Combined molecular MRI and immuno-spin trapping for in vivo detection of free radicals in orthotopic mouse GL261 glioma; Elsevier; Biochimica et Biophysica Acta - Molecular Basis of Disease; 1832; 12; 12-2013; 2153-2161 | es |
| dc.identifier.issn | 0925-4439 | es |
| dc.identifier.uri | http://hdl.handle.net/11336/4362 | |
| dc.journal.ciudad | Amsterdam | es |
| dc.journal.number | 12 | es |
| dc.journal.pagination | 2153-2161 | es |
| dc.journal.pais | Países Bajos | es |
| dc.journal.title | Biochimica et Biophysica Acta - Molecular Basis of Disease | es |
| dc.journal.volume | 1832 | es |
| dc.language.iso | eng | es |
| dc.publisher | Elsevier | es |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S092544391300269X | |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.bbadis.2013.08.004 | |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/issn/0925-4439 | |
| dc.rights | info:eu-repo/semantics/openAccess | * |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ | * |
| dc.subject | Glioma | es |
| dc.subject | Free Radical | es |
| dc.subject | Immuno-Spin Trapping | es |
| dc.subject | Mri | es |
| dc.subject.classification | Neurociencias | es |
| dc.subject.classification | Medicina Básica | es |
| dc.subject.classification | CIENCIAS MÉDICAS Y DE LA SALUD | es |
| dc.title | Combined molecular MRI and immuno-spin trapping for in vivo detection of free radicals in orthotopic mouse GL261 glioma | es |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:ar-repo/semantics/artículo | |
| dc.type | info:eu-repo/semantics/publishedVersion | |
Archivos
Bloque original
Cargando...
- Nombre:
- CONICET_Digital_Nro.5788_A.pdf
- Tamaño:
- 683.93 KB
- Formato:
- Adobe Portable Document Format
- Descripción: