Room-temperature fluorescence spectroscopy of monohydroxy metabolites of polycyclic aromatic hydrocarbons on octadecyl extraction membranes | ||
| dc.conicet.organizacion | University of Central Florida | |
| dc.conicet.organizacion | University of Central Florida | |
| dc.conicet.organizacion | Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe | |
| dc.conicet.organizacion | University of Central Florida | |
| dc.contributor.author | Calimag Williams, Korina | |
| dc.contributor.author | Goicoechea, Hector Casimiro | |
| dc.contributor.author | Campiglia, Andres D. | |
| dc.date.issued | 2011-09 | |
| dc.description.abstract | Urine analysis of monohydroxy metabolites is recognized as an accurate assessment of human exposure to polycyclic aromatic hydrocarbons. Despite the sophisticated arsenal of analytical tools, monitoring of monohydroxy metabolites via simple, cost effective and direct methods of analysis still remains a challenge. This article evaluates the analytical potential of solid-phase extraction room-temperature fluorescence spectroscopy for the problem at hand. Extraction membranes serve the dual purpose of sample pre-concentration and solid substrate for RTF measurements. The potential of our proposition is demonstrated with the analysis of 2-hydroxy-fluorene, 1-hydroxy-pyrene, 3-hydroxy-benzo[a]pyrene and 9-hydroxy-phenanthrene in synthetic urine samples. Signal reproducibility is improved with the aid of a sample holder specifically designed for the manual optimization of luminescence signals. Background correction of solid substrates is carried out with the aid of Asymmetric Least Squares. Recovery values for the studied metabolites varied from 99.0 ± 1.2% (3-hydroxy-benzo[a]pyrene) to 99.9 ± 0.05% (1-hydroxy-pyrene). With only 10 mL of urine sample, the limits of detection varied from 57 pg mL -1 (2-hydroxy-fluorene) to 2 pg mL-1 (1-hydroxy-pyrene). Additional figures of merit include a simple experimental procedure for routine screening of numerous samples and compatibility with portable instrumentation for field analysis. Because of the non-destructive nature of fluorescence measurements, membranes can be brought to the lab for subsequent elution and confirmation of compounds via high-resolution techniques. | es |
| dc.description.fil | Fil: Calimag Williams, Korina. University of Central Florida; Estados Unidos | |
| dc.description.fil | Fil: Goicoechea, Hector Casimiro. University of Central Florida; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe; Argentina | |
| dc.description.fil | Fil: Campiglia, Andres D.. University of Central Florida; Estados Unidos | |
| dc.format | application/pdf | es |
| dc.identifier.citation | Calimag Williams, Korina; Goicoechea, Hector Casimiro; Campiglia, Andres D.; Room-temperature fluorescence spectroscopy of monohydroxy metabolites of polycyclic aromatic hydrocarbons on octadecyl extraction membranes; Elsevier Science; Talanta; 85; 4; 9-2011; 1805-1811 | es |
| dc.identifier.institucional | CONICET | |
| dc.identifier.issn | 0039-9140 | es |
| dc.identifier.repo | CONICET Digital | |
| dc.identifier.uri | http://hdl.handle.net/11336/74181 | |
| dc.journal.ciudad | Amsterdam | es |
| dc.journal.number | 4 | es |
| dc.journal.pagination | 1805-1811 | es |
| dc.journal.pais | Países Bajos | es |
| dc.journal.title | Talanta | es |
| dc.journal.volume | 85 | es |
| dc.language.iso | eng | es |
| dc.publisher | Elsevier Science | es |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.talanta.2011.07.009 | |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914011005844 | |
| dc.rights | info:eu-repo/semantics/openAccess | * |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | * |
| dc.subject | Asymmetric Least Squares | es |
| dc.subject | Monohydroxy Metabolites | es |
| dc.subject | Polycyclic Aromatic Hydrocarbons | es |
| dc.subject | Room-Temperature Fluorescence | es |
| dc.subject | Solid-Phase Extraction | es |
| dc.subject | Urine Analysis | es |
| dc.subject.classification | Otras Ciencias Químicas | es |
| dc.subject.classification | Ciencias Químicas | es |
| dc.subject.classification | CIENCIAS NATURALES Y EXACTAS | es |
| dc.title | Room-temperature fluorescence spectroscopy of monohydroxy metabolites of polycyclic aromatic hydrocarbons on octadecyl extraction membranes | es |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:ar-repo/semantics/artículo | |
| dc.type | info:eu-repo/semantics/publishedVersion | |
Archivos
Bloque original
Cargando...
- Nombre:
- CONICET_Digital_Nro.e727dc70-aac2-456c-8405-d8f33aebc206_A.pdf
- Tamaño:
- 634.49 KB
- Formato:
- Adobe Portable Document Format