Artículo

High-Dose Plasmid-Mediated VEGF Gene Transfer is Safe in Patients With Severe Ischemic Heart Disease (GENESIS-I): A Phase I, Open-Label, Two-Year Follow-up Trial

Favaloro, Liliana ; Diez, Mirta ; Mendiz, Oscar ; Vera Janavel, Gustavo ; Valdivieso, León ; Ratto, Roxana ; Garelli, Guillermo ; Salmo, Fabián ; Criscuolo, Marcelo ; Bercovich, Andrés ; Crottogini, Alberto Jose Icon

Otros responsables

Fecha

2013-11-15

Editorial

Wiley

Revista

Catheterization And Cardiovascular Interventions : Official Journal Of The Society For Cardiac Angiography & Interventions.

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1522-1946

eISSN

1522-726X

ISBN

Idioma

Inglés

Tipo del evento

Resumen

Objectives: We aimed to assess safety and, secondarily, the efficacy of intramyocardial high-dose plasmid-vascular endothelial growth factor (VEGF) 165 (pVEGF165) gene transfer in no-option patients with coronary artery disease (CAD). Background: Controlled trials of pVEGF165 in CAD have shown little benefit. One possible reason is shortness of dosage. We have shown in large mammalian models of chronic myocardial ischemia and acute myocardial infarction that intramyocardial pVEGF165 at doses significantly higher than those used in recent phase II trials is safe and efficacious on myocardial perfusion, left ventricular function, and infarct size limitation. Methods: Using an injection catheter, 10 patients with severe CAD not amenable for revascularization received 10 intramyocardial injections of 0.38 mg (total dose, 3.8 mg) pVEGF165 in zones exhibiting myocardial ischemia, as assessed by combined stress 99mTc-sestamibi single-photon emission computed tomography and stress echocardiography. Results: No serious adverse events related to either VEGF or the injection procedure occurred over the 2-year follow-up. One patient suffered femoral artery thrombosis after a follow-up coronary angiography, successfully resolved with medical treatment. Six patients suffered uncomplicated coronary ischemic events during the second year follow-up. Angina functional class decreased from 2.6 6 0.2 to 1.2 6 0.3 (mean 6 SEM, P < 0.05), quality of life increased from 56.9 6 3.2 to 82.6 6 2.4 (P < 0.05), the summed difference score of myocardial perfusion decreased from 13.4 6 2 to 7.7 6 1.8 (P < 0.04), and stress ejection fraction did not change (44.2 6 3.6% to 47.8 6 3.1%, P 5 NS). Conclusions: High-dose intramyocardial pVEGF165 is safe at 2 years follow-up in patients with severe CAD. The efficacy results observed must be taken cautiously given the uncontrolled, open-label study design.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa