Calibration of the underground muon detector of the Pierre Auger Observatory

Aab, A. ; Abreu, P. ; Aglietta, M. ; Albury, J. M. ; Allekotte, Ingomar ; Almela, A. ; Alvarez Muñiz, J. ; Alves Batista, R. ; Anastasi, G. A. ; Anchordoqui, Luis A. Icon; Andrada, B. ; Andringa, S. ; Aramo, C. ; Araújo Ferreira, P. R. ; Arteaga Velázquez, J. C. ; Asorey, Hernán Gonzalo Icon; Assis, P. ; Avila, G. ; Badescu, A.M. ; Bakalova, A. ; Balaceanu, A. ; Barbato, F. ; Barreira Luz, R. J. ; Becker, K. H. ; Bellido, J. A. ; Berat, C. ; Bertaina, M. E. ; Bertou, Xavier Pierre Louis Icon; Biermann, P. L. ; Gollan Scilipotti, Fernando Daniel Icon

Otros responsables

Fecha

04/2021

Editorial

IOP Publishing

Revista

Journal of Instrumentation

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1748-0221

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

To obtain direct measurements of the muon content of extensive air showers with energy above 101 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m2-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m close to the intersection of the shower axis with the ground to much less than one per m when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by