Resumen

Atom probe tomography (APT) is a powerful microscopy technique to characterize nano-sized clusters of the alloying elements in the bulk of reactor pressure vessel (RPV) steels, which are known to dominantly determine the evolution of mechanical properties under irradiation. The results are conventionally summarized as the overall number density N and the average diameter D of the solute clusters identified in the material. Here, we demonstrate that these descriptors are intrinsically imprecise because they are steered by the parameters involved in the measurement and data processing, some of which are directly under the control of the operators, and some others not. Consequently, a direct comparison between data derived at different laboratories is compromised, and key trends such as the evolution with dose, are masked. This study relies on a state-of-the-art physical model for neutron irradiation in steels to make reliable estimates of the true microstructure before the measurement is performed, which allows to predict what population of solute clusters are not seen. We mimic APT measurements from simulated microstructures, performing a detailed study of the effects of the parameters of the analysis. We show that the values of N and D reported in the scientific literature can be matched by the predictions of our theoretical model only if specific sets of parameters are used for each laboratory that issued the measurements. We also show that if, on the contrary, all studied cases are analysed in a consistent way, the scatter of N and D values is reduced. Specifically, we find that the average diameter D is nearly a constant value with dose, independently of the material’s chemical compositions, and the that the Fe content in the solute clusters is most likely large (> 50%) even before the measurement is performed.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa