Development of a voltammetric electronic tongue for the simultaneous determination of synthetic antioxidants in edible olive oils
; Zon, María Alicia
; Fernandez, Hector
; Granero, Adrian Marcelo
; Robledo, Sebastian Noel
; Pierini, Gastón Dario 
Otros responsables
Fecha
08/2023
Editorial
Elsevier Science
Revista
Talanta
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0039-9140
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
A voltammetric electronic tongue (E-tongue) is “a multisensor system, which consists of a number of low-selective sensors and uses advanced mathematical procedures for signal processing based on pattern recognition and/or data multivariate analysis such as artificial neural networks (ANNs), principal component analysis (PCA), among others”. Thus, E-tongues in combination with chemometrics tools result in more accurate and selective analytical methods. In this work, we report results of a simple and reliable electroanalytical method to determine butyl hydroxyanisole (BHA), butyl hydroxytoluene (BHT) and propyl gallate (PG) in edible olive oils (EOO). Therefore, the square wave voltammetry (SWV) was used on platinum and carbon fiber disk ultramicroelectrodes (E-tongue configuration) combined with chemometrics tools to perform these studies. On the other hand, two data fusion strategies were used in order to combine electrochemical data obtained for each working electrode in the E-tongue: low-level data fusion (LLDF) and mid-level data fusion (MLDF). In addition, to reduce the dimensionality of the dataset in MLDF, the discrete wavelet transform (DWT) was used. Finally, to assert the predictive capability of the method for BHA, BHT, and PG determination in real samples, a recovery study for the antioxidants in EOO samples was performed, demonstrating the analytical accuracy of the proposed method. Moreover, from the comparison between the proposed electrochemical method with the AOAC reference method and others found in the literature in terms of the quality of the model (REP %) and the percent recovery assays (%) in different samples, our results were better than other reported previously for the simultaneous determination of BHA, BHT, and PG in real samples. Moreover, the percent recovery assays obtained with the proposed electrochemical method were in good agreement with those obtained by the chromatographic method.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa
