<link rel="stylesheet" href="/res/styles.39be4579664c3a48.css">
Artículo

Multi-view hybrid graph convolutional network for volume-to-mesh reconstruction in cardiovascular MRI

Gaggion Zulpo, Rafael Nicolás Icon; Matheson, Benjamin A. ; Xia, Yan ; Bonazzola, Rodrigo ; Ravikumar, Nishant ; Taylor, Zeike A. ; Milone, Diego Humberto Icon; Frangi, Alejandro ; Ferrante, Enzo Icon

Otros responsables

Fecha

05/2025

Editorial

Elsevier Science

Revista

Medical Image Analysis

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1361-8415

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

Cardiovascular magnetic resonance imaging is emerging as a crucial tool to examine cardiac morphology and function. Essential to this endeavour are anatomical 3D surface and volumetric meshes derived from CMR images, which facilitate computational anatomy studies, biomarker discovery, and in-silico simulations. Traditional approaches typically follow complex multi-step pipelines, first segmenting images and then reconstructing meshes, making them time-consuming and prone to error propagation. In response, we introduce HybridVNet, a novel architecture for direct imageto-mesh extraction seamlessly integrating standard convolutional neural networks with graph convolutions, which we prove can efficiently handle surface and volumetric meshes by encoding them as graph structures. To further enhance accuracy, we propose a multi-view HybridVNet architecture which processes both long axis and short axis CMR, showing that it can increase the performance of cardiac MR mesh generation. Our model combines traditional convolutional networks with variational graph generative models, deep supervision and mesh-specific regularisation. Experiments on a comprehensive dataset from the UK Biobank confirm the potential of HybridVNet to significantly advance cardiac imaging and computational cardiology by efficiently generating high-fidelity meshes from CMR images. Multi-view HybridVNet outperforms the state-of-the-art, achieving improvements of up to ∼27% reduction in Mean Contour Distance (from 1.86 mm to 1.35 mm for the LV Myocardium), up to ∼18% improvement in Hausdorff distance (from 4.74 mm to 3.89mm, for the LV Endocardium), and up to ∼8% in Dice Coefficient (from 0.78 to 0.84, for the LV Myocardium), highlighting its superior accuracy.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa