Water-equivalence of gel dosimeters for radiology medical imaging
; Vedelago, José Alberto
; Chacón Obando, David ; Mattea, Facundo
; Velásquez, José ; Pérez, Pedro Antonio 
Otros responsables
Fecha
11/2018
Editorial
Pergamon-Elsevier Science Ltd
Revista
Applied Radiation and Isotopes
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0969-8043
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent; that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 kVp) were found to be less than 3% in average.