Artículo

Impact of surface treatments on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications

Pereda, M. D. ; Kang, Kyung Won ; Bonetto, Rita Dominga Icon; Llorente, Carlos Luis ; Bilmes, Pablo David Icon; Gervasi, Claudio

Otros responsables

Fecha

06/2012

Editorial

Elsevier

Revista

Procedia Materials Science

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

2211-8128

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

AISI 316 LVM stainless steel type considered in ASTM F138 and F139 standards for implant devices is widely used, in particular for orthopedic surgery, because it combines good biofunctionality and acceptable biocompatibility at low costs. Adequate interaction of these materials with the human body and its capability to reach the desired service level are determined by the surface preparation. The goal of the present work is to relate the surface roughness parameters with the localized corrosion resistance of AISI 316 LVM stainless steel grit blasted for different times and passivated with nitric acid. At intermediate blasting times the roughness parameters attain an extreme value and this surface condition corresponds with the maximum pitting corrosion resistance.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd