Artículo

Load management: Model-based control of aggregate power for populations of thermostatically controlled loads

Perfumo, Cristian ; Kofman, Ernesto Javier Icon; Braslavsky, Julio H. ; Ward, John K.

Otros responsables

Fecha

03/2012

Editorial

Elsevier

Revista

Energy Conservation And Management

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0196-8904

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

Large groups of electrical loads can be controlled as a single entity to reduce their aggregate power demand in the electricity network. This approach, known as load management (LM) or demand response, offers an alternative to the traditional paradigm in the electricity market, where matching supply and demand is achieved solely by regulating how much generation is dispatched. Thermostatically controlled loads (TCLs), such as air conditioners (ACs) and fridges, are particularly suitable for LM, which can be implemented using feedback control techniques to regulate their aggregate power. To achieve high performance, such feedback control techniques require an accurate mathematical model of the TCL aggregate dynamics. Although such models have been developed, they appear too complex to be effectively used in control design. In this paper we develop a mathematical model aimed at the design of a model-based feedback control strategy. The proposed model analytically characterises the aggregate power response of a population of ACs to a simultaneous step change in temperature set points. Based on this model, we then derive, and completely parametrise in terms of the ACs ensemble properties, a reduced-order mathematical model to design an internal-model controller that regulates aggregate power by broadcasting temperature set-point offset changes. The proposed controller achieves high LM performance provided the ACs are equipped with high resolution thermostats. With coarser resolution thermostats, which are typical in present commercial and residential ACs, performance deteriorates significantly. This limitation is overcome by subdividing the population into clusters of ACs that receive a coarse-grained, cluster-dependent control signal. The proposed clustering technique recovers the performance achieved with high resolution thermostats at the expense of some additional comfort penalty, which can be quantified using the controller output.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd