Artículo

Scanning Electrochemical Microscopy #54. Application To The Study Of Heterogeneous Catalytic ReactionsHydrogen Peroxide Decomposition

Fernandez, Jose Luis Icon; Hurth, Cedric ; Bard, Allen

Otros responsables

Fecha

05/2005

Editorial

American Chemical Society

Revista

Journal of Physical Chemistry B

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1520-6106

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Palabras clave

Resumen

A scanning electrochemical microscopy (SECM) approach for the analysis of heterogeneous catalytic-reactions at solid-liquid interfaces is described and applied. In this scheme reactant, generated at a tip, undergoes a reaction, e.g. disproportionation, at the substrate.  The theoretical background for this study, performed by digital simulations using a finite difference method, considers a chemical reaction at the substrate with general stoichiometry. In this case the fraction of regenerated mediator (nS) may differ with respect to a substrate reaction that is the reverse of the tip reaction, resulting in an asymmetric mediator loop. Simulated tip current transients and approach curves at different values of the kinetic rate constant for reactions where nS < 1 were used to analyze this new SECM situation. This approach was used to study the catalytic decomposition of hydrogen peroxide (HO2- ® 1/2O2 + OH-), where nS = 0.5, on supported catalysts. A gold-mercury amalgam tip was used to quantitatively reduce dissolved O2 (mediator) to HO2-, which was decomposed back to oxygen at the catalyst substrate. Rate constants for the decomposition reaction on immobilized catalase and Pt particles were measured at different pH values by correlation of experimental approach curves with the theoretical dependencies.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa