Microstructural, mechanical and electrochemical characterisation of biomaterial ASTM F745 cast by vacuum

Otros responsables
Fecha
06/2012
Editorial
Maney Publishing
Revista
Materials Science and Technology
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0267-0836
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Countergravity low pressure casting (CLA) was performed to enhance the properties of ASTMF745 stainless steel (SS), which is usually used as biomaterial. The macro- and microstructureswere compared with those obtained by the conventional process of investment casting (IC). TheSS cast by CLA (SSCLA) exhibited a smaller size of solidification cell and finer dendriticmicrostructure. The average of its dendritic primary spacing was 110·4 mm, while for the same steel cast by IC (SSIC), it was 186·7 μm. The density of non-metallic inclusions δ in the SSCLA was 717 I mm -2, being the majority of them smaller than 1·5 mm. In the case of SSIC, dI was 852 I mm -2, with a size distribution of up to 8 μm. The SSCLA showed a higher breakdown potential than the SSIC, the values being 0·p300 and 0·210 V(saturated calomel electrode) respectively, which means a higher resistance to suffer localised corrosion. Finely, the CLA process also allowed obtaining better mechanical properties.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa