QUBIC V: Cryogenic system design and performance

Masi, S. ; Battistelli, E. S. ; De Bernardis, P. ; Chapron, C. ; Columbro, F. ; Coppolecchia, A. ; D’Alessandro, G. ; De Petris, M. ; Grandsire, L. ; Hamilton, J. C. ; Lamagna, L. ; Marnieros, S. ; Mele, L. ; May, A. ; Almela, Daniel Alejandro Icon; Cobos Cerutti, Agustin Cleto Icon; Duca, Clara Icon; Etchegoyen, Alberto Icon; Ferreyro, Luciano Pablo Icon; Gamboa Lerena, Martín Miguel Icon; García Redondo, Manuel Elías Icon; Hampel, Matias Rolf Icon; Harari, Diego Dario Icon; Melo, Diego Gabriel Icon; Pastoriza, Hernan Icon; Platino, Manuel Icon; Rasztocky, Emiliano Icon; Scoccola, Claudia Graciela Icon; Supanitsky, Alberto Daniel Icon; Wright, María Icon

Otros responsables

Fecha

10/2021

Editorial

IOP Publishing

Revista

Journal of Cosmology and Astroparticle Physics

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1475-7516

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays with cold optical systems to boost their mapping speed. For this reason, large volume cryogenic systems with large optical windows, working continuously for years, are needed. The cryogenic system of the QUBIC (Q & U Bolometric Interferometer for Cosmology) experiment solves a combination of simultaneous requirements: very large optical throughput (∼40 cm2sr), large volume (∼1 m3) and large mass (∼165 kg) of the cryogenic instrument. Here we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat that uses two pulse-tube refrigerators to cool the instrument to ∼3 K. The instrument includes the cryogenic polarization modulator, the corrugated feedhorn array, and the lower temperature stages: a 4He evaporator cooling the interferometer beam combiner to ∼1 K and a 3He evaporator cooling the focal-plane detector arrays to ∼0.3 K. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33 K, while the polarization modulator has operated at a ∼10 K base temperature. The system has been tilted to cover the boresight elevation range 20°-90° without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by