Artículo

Theoretical Investigation of Nanoparticle Relaxation for Magnetic Hyperthermia Applications: Effects of Size, Anisotropy, and Interparticle Distance Distributions

Valdés, Daniela Paola Icon; Lima, Enio Junior Icon; Zysler, Roberto Daniel Icon; de Biasi, Emilio Icon

Otros responsables

Fecha

05/2025

Editorial

American Chemical Society

Revista

ACS Applied Nano Materials

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

2574-0970

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

Theoretical models on the relaxation of magnetic nanoparticles are  essential for designing optimized systems for biomedical applications like Magnetic Hyperthermia. However, existing models often assume uniform, ideal magnetic nanoparticles in noninteracting systems or simple, equidistant magnetic nanoparticle assemblies, which do not accurately reflect experimental complexities. Parameter distributions are expected to modify the AC hysteresis loop of the system and, consequently, the power absorption from the magnetic field, as it is proportional to its enclosed area. However, studies on this impact remain limited. In this article, we investigate the magnetic relaxation in Magnetic Hyperthermia conditions of noninteracting magnetic nanoparticle systems with typical experimental size and anisotropy-constant distributions for two easy-axis configurations: oriented parallel to the applied field and randomly oriented. Additionally, we analyze magnetic nanoparticles arranged into chains with a dispersion in interparticle distances. Our findings reveal that the irreversibility of hysteresis loops increases with the coefficient of variation of all distributions considered when easy-axes are aligned with the external magnetic field, but this effect is diminished by random orientation. Furthermore, we correlate internal structures formed by the dispersion of interparticle distances in chains with said increase of irreversibility. Coercivity is modified by size distributions, while susceptibility is modified by anisotropy constant distributions. As irreversibility, coercivity and susceptibility impact on the hysteresis loop area, studying their change with realistic parameter distributions is critical to improve and understand Magnetic Hyperthermia performance, filling the gap between theory and experiment.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa