Artículo

A CFD analysis of the influence of plenum configurations on gas distribution in a fluidized bed

Soria, Jose Miguel Icon; Ausina, T. M. ; Mazza, German Delfor Icon

Otros responsables

Fecha

04/2020

Editorial

Planta Piloto de Ingeniería Química

Revista

Latin American Applied Research

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0327-0793

eISSN

1851-8796

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

Fluidized beds are widely used in many industries. The fluidization quality of these units is strongly related to the characteristics of the plenum and distributor (grid). In this work, the effect of different plenum geometries, and gas entrance sizes and locations on the velocity profile above the distributor was analyzed by Computational Fluid Dynamics (CFD). The results showed that flow uniformity above the distributor improved with an increase in the gas inlet diameter and the plenum height. Channeling was observed for the bottom central inlet. Addition-ally, simulations for plenum heights predicted by one of the frequently used correlations (Litz correlation) were also carried out and showed, especially for a bot-tom central gas inlet, a poor quality flow distribution. This behavior indicated that Litz correlation tends to underestimate the plenum height for obtaining a uni-form flow downstream the distributor.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd