Applied to IPA dehydration, this paper analyses the economic and environmental performance of two variants of the hybrid distillation/pervaporation process operated in batch wise mode; namely, distillation followed by pervaporation with either a polymeric membrane or a ceramic membrane. Both variants are also compared from an environmental standpoint resorting to a life cycle analysis (LCA). Conceptual models of the distillation step and the pervaporation stage were used in doing the performance comparison of variants considering commercial membranes CMC-CF-23 and HybSi. To build the conceptual model for the HybSi membrane, six dehydration experiments were conducted, starting with a feed composition of 80 wt% IPA at three temperatures (70 °C, 80 °C, and 90 °C) and two vacuum levels (3.7 and 6.7 kPa). A permeance model, incorporating the active pore fraction as a parameter, was fitted and showed good agreement with the experimental data. Finally, in order to improve the environmental performance of the distillation/HybSi variant, simulations of the pervaporation task at 90 °C with two vacuum levels (9.7 kPa, 6.7 kPa) consecutively applied were done. This variant was the most attractive from both an economic and environmental point of view. The resulting recovery cost at the optimum was 690 US$ t−1 and the operation at 90 °C was characterized by a distillate composition of 82 % by weight of IPA, a permeate flux of 2.64 kg m−2 h−1 and a permeate composition of 2.7 % IPA by weight. The consecutive condensation temperatures of permeates were 33 °C and 11 °C, respectively. As initially supposed, an enhancement of the environmental performance of this alternative with respect to the others measured from both a life cycle emissions (LCE) perspective and a life cycle impact assessment (LCIA) on human health, ecosystems and resources occurred.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa