Spectroelectrochemical examination of the interaction between bacterial cells and gold electrodes

Busalmen, Juan Pablo Icon; Berna, Antonio ; Feliu, Juan Miguel

Otros responsables

Fecha

05/2007

Editorial

American Chemical Society

Revista

Langmuir

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0743-7463

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

The interaction between bacterial cells of Pseudomonas fluorescens (ATCC 17552) and gold electrodes was analyzed by cyclic voltammetry (CV) and attenuated total reflection-surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS). The voltammetric evaluation of cell adsorption showed a decrease in the double-layer capacitance of polyoriented single-crystal gold electrodes with cell adhesion. As followed by IR spectroscopy in the ATR configuration, the adsorption of bacterial cells onto thin-film gold electrodes was mainly indicated by the increase in intensity with time of amide I and amide II protein-related bands at 1664 and 1549 cm-1, respectively. Bands at 1448 and 2900 cm-1 corresponding to the scissoring and the stretching bands of CH2 were also detected, together with a minor peak at 1407 cm-1 due to the vs COO- stretching. Weak signals at 1237 cm-1 were due to amide III, and a broad band between 1100 and 1200cm-1 indicated the presence of alcohol groups. Bacteria were found to displace water molecules and anions coadsorbed on the surface in order to interact with the electrode intimately. This fact was evidenced in the SEIRAS spectra by the negative features appearing at 3450 and 3575 cm -1, corresponding to interfacial water directly interacting with the electrode and water associated with chloride ions adsorbed on the electrode, respectively. Experiments in deuterated water confirmed these assignments and allowed a better estimation of amide absorption bands. In CV experiments, an oxidation process was observed at potentials higher than 0.4 V that was dependent on the exposure time of electrodes in concentrated bacterial suspensions. Adsorbed bacterial cells were found to get closer to the gold surface during oxidation, as indicated by the concomitant increment in the main IR bacterial signals including amideI, a sharp band at 1240 cm-1, and a broad one at 1120 cm-1 related to phosphate groups in the bacterial membranes. It is proposed to be due to the oxidation of lipopolysaccharides on the outermost bacterial surface. © 2007 American Chemical Society.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa