Artículo

External validation of a shortened screening tool using individual participant data meta-analysis: A case study of the Patient Health Questionnaire-Dep-4

Harel, Daphna ; Levis, Brooke ; Sun, Ying ; Fischer, Felix ; Ioannidis, John P.A. ; Cuijpers, Pim ; Patten, Scott B. ; Ziegelstein, Roy C. ; Markham, Sarah ; Benedetti, Andrea ; Thombs, Brett D. ; He, Chen ; Wu, Yin ; Krishnan, Ankur ; Mani Bhandari, Parash ; Neupane, Dipika ; Negeri, Zelalem ; Imran, Mahrukh ; Rice, Danielle B. ; Riehm, Kira E. ; Azar, Marleine ; Levis, Alexander W. ; Boruff, Jill ; Gilbody, Simon ; Kloda, Lorie A. ; Amtmann, Dagmar ; Ayalon, Liat ; Baradaran, Hamid R ; Beraldi, Anna ; Daray, Federico Manuel Icon

Otros responsables

Fecha

11/2021

Editorial

Academic Press Inc Elsevier Science

Revista

Methods

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1046-2023

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

Shortened versions of self-reported questionnaires may be used to reduce respondent burden. When shortened screening tools are used, it is desirable to maintain equivalent diagnostic accuracy to full-length forms. This manuscript presents a case study that illustrates how external data and individual participant data meta-analysis can be used to assess the equivalence in diagnostic accuracy between a shortened and full-length form. This case study compares the Patient Health Questionnaire-9 (PHQ-9) and a 4-item shortened version (PHQ-Dep-4) that was previously developed using optimal test assembly methods. Using a large database of 75 primary studies (34,698 participants, 3,392 major depression cases), we evaluated whether the PHQ-Dep-4 cutoff of ≥ 4 maintained equivalent diagnostic accuracy to a PHQ-9 cutoff of ≥ 10. Using this external validation dataset, a PHQ-Dep-4 cutoff of ≥ 4 maximized the sum of sensitivity and specificity, with a sensitivity of 0.88 (95% CI 0.81, 0.93), 0.68 (95% CI 0.56, 0.78), and 0.80 (95% CI 0.73, 0.85) for the semi-structured, fully structured, and MINI reference standard categories, respectively, and a specificity of 0.79 (95% CI 0.74, 0.83), 0.85 (95% CI 0.78, 0.90), and 0.83 (95% CI 0.80, 0.86) for the semi-structured, fully structured, and MINI reference standard categories, respectively. While equivalence with a PHQ-9 cutoff of ≥ 10 was not established, we found the sensitivity of the PHQ-Dep-4 to be non-inferior to that of the PHQ-9, and the specificity of the PHQ-Dep-4 to be marginally smaller than the PHQ-9.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa