Artículo

Multisensory Stimulation and EEG Recording below the Hair-Line: A New Paradigm on Brain Computer Interfaces

Carmona Viglianco, Victor Luciano Icon; Diez, Pablo Federico Icon; Laciar Leber, Eric Icon; Mut, Vicente Antonio Icon

Otros responsables

Fecha

04/2020

Editorial

Institute of Electrical and Electronics Engineers

Revista

Ieee Transactions On Neural Systems And Rehabilitation Engineering

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1534-4320

eISSN

1558-0210

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

To test the feasibility of implementing multisensory (auditory and visual) stimulation in combination with electrodes placed on non-hair positions to design more efficient and comfortable Brain-computer interfaces (BCI). Fifteen volunteers participated in the experiments. They were stimulated by visual, auditory and multisensory stimuli set at 37, 38, 39 and 40Hz and at different phases (0◦, 90◦, 180◦ and 270◦). The electroencephalogram (EEG) was measured from Oz, T7, T8, Tp9 and Tp10 positions. To evaluate the amplitude of the visual and auditory evoked potentials, the signal-to-noise ratio (SNR) was used and the accuracy of detection was calculated using canonical correlation analysis. Additionally, the volunteers were asked about the discomfort of each kind of stimulus. The multisensory stimulation allows for attaining higher SNR on every electrode. Non-hair (Tp9 and Tp10) positions attained SNR and accuracy similar to the ones obtained from occipital positions on visual stimulation. No significant difference was found on the discomfort produced by each kind of stimulation. The results demonstrated that multisensory stimulation can help in obtaining high amplitude steady-state evoked responses with a similar discomfort level. Then, it is possible to design a more efficient and comfortable hybrid-BCI based on multisensory stimulation and electrodes on non-hair positions. The current article proposes a new paradigm for hybrid-BCI based on steadystate evoked potentials measured from the area behind-theears and elicited by multisensory stimulation, thus, allowing subjects to achieve similar performance to the one achieved by visual-occipital BCI, but measuring the EEG on a more comfortable electrode location.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa