Exactitud del Xiaomi Mi Band 4 para contabilizar pasos en adultos con enfermedades respiratorias crónicas: Estudio de concordancia | ||
| dc.conicet.organizacion | Hospital Italiano | |
| dc.conicet.organizacion | Instituto de Salud Global de Barcelona | |
| dc.conicet.organizacion | Instituto de Salud Global de Barcelona | |
| dc.conicet.organizacion | Hospital Italiano | |
| dc.conicet.organizacion | Hospital Italiano | |
| dc.conicet.organizacion | Hospital Italiano | |
| dc.conicet.organizacion | Hospital Italiano | |
| dc.conicet.organizacion | Hospital Italiano | |
| dc.conicet.organizacion | Hospital Italiano | |
| dc.conicet.organizacion | Consejo Nacional de Investigaciones Científicas y Técnicas | |
| dc.contributor.author | Dell'era, Silvina | |
| dc.contributor.author | Gimeno Santos, Elena | |
| dc.contributor.author | Fiad Chain, Nahir Ayleen | |
| dc.contributor.author | Castellano Barneche, María Florencia | |
| dc.contributor.author | Macario Turón, Gonzalo | |
| dc.contributor.author | Bykhovsky, Ilona | |
| dc.contributor.author | Carolina Balestrieri, María Carolina | |
| dc.contributor.author | Gracia, Guadalupe | |
| dc.contributor.author | Terrasa, Sergio Adrian | |
| dc.date.issued | 2024-06 | |
| dc.description.abstract | Introducción: El Xiaomi Mi Band 4 (XMB4) demostró ser exacto para medir pasos en sujetos sanos, pero no ha sido estudiado en pacientes con enfermedades respiratorias crónicas (ERC).Objetivos: Evaluar la exactitud del XMB4 para cuantificar pasos caminados en pacientescon ERC. Secundariamente, evaluar su viabilidad y usabilidad.Material y métodos: Estudio de concordancia contrastando los datos del XMB4 con la video-filmación (prueba de referencia). Fueron incluidos mayores de 18 años con diversas ERC y excluidos aquellos con deterioro cognitivo, limitaciones osteoarticulares y/o cardiovasculares que impedían la marcha. Realizamos un muestreo por conveniencia de pacientes que participaban de un programa de rehabilitación pulmonar. Las variables estudiadas incluyeron número de pasos, distancia y tiempo caminado, velocidad de la marcha, viabilidad y usabilidad. Cada participante realizó cinco caminatas (5, 10 y 30 metros, y 5 minutos a ritmo lento y rápido). Para testear la equivalencia estadística, necesitamos incluir 33 pacientes y utilizamos el método de intervalo de confianza con una zona de equivalencia de ±15%. Resultados: Fueron incluidos 33 pacientes, 64% mujeres, con una mediana (P25-75) de edad de 64,9 (55,8 a 70,2) años. Los pasos registrados por el XMB4 fueron equivalentes a los de la video-filmación en las diferentes caminatas, excepto en la de 5 metros. Los pasos fueron subestimados con un error de medición menor al 15%. Conclusiones: El XMB4 tiene una exactitud aceptable para medir pasos en pacientes con ERC excepto en caminatas muy cortas, es viable y fácil de usar. | es |
| dc.description.abstract | Introduction: Xiaomi Mi Band 4 (XMB4) has been shown to be accurate to measure steps in healthy subjects, but has not been studied in patients with chronic respiratory diseases (CRD). Objectives: To evaluate the accuracy of the XMB4 to quantify steps walked in patients with CRD. Secondarily, evaluate its feasibility and usability. Materials and methods: Agreement study compared the XMB4 data with the video (reference test). Adults aged 18 years or older with various CRD were included and those with cognitive impairment, osteoarticular and/or cardiovascular limitations that prevented walking were excluded. We conducted a convenience sampling of patients participating in a pulmonary rehabilitation program. Outcome measures studied included number of steps, distance and time walked, walking speed, feasibility and usability. Each participant performed five walks (5, 10 and 30 meters, and 5 minutes at a slow and fast pace). To test statistical equivalence we need to include 33 patients and use the confidence interval method with an equivalence zone of ±15%. Results: 33 patients were included, 64% women, with a median (P25-75) age of 64.9 (55.8 to 70.2) years. The steps recorded by the XMB4 were equivalent to those of the video in the different walks, except for the 5-meter walk. The steps were underestimated with a measurement error of less than 15%. Conclusions: XMB4 has acceptable accuracy for measuring steps in patients with CRD except for very short walks, it is feasible and easy to use. | es |
| dc.description.fil | Fil: Dell'era, Silvina. Hospital Italiano; Argentina | |
| dc.description.fil | Fil: Gimeno Santos, Elena. Instituto de Salud Global de Barcelona; España | |
| dc.description.fil | Fil: Fiad Chain, Nahir Ayleen. Instituto de Salud Global de Barcelona; España | |
| dc.description.fil | Fil: Castellano Barneche, María Florencia. Hospital Italiano; Argentina | |
| dc.description.fil | Fil: Macario Turón, Gonzalo. Hospital Italiano; Argentina | |
| dc.description.fil | Fil: Bykhovsky, Ilona. Hospital Italiano; Argentina | |
| dc.description.fil | Fil: Carolina Balestrieri, María Carolina. Hospital Italiano; Argentina | |
| dc.description.fil | Fil: Gracia, Guadalupe. Hospital Italiano; Argentina | |
| dc.description.fil | Fil: Terrasa, Sergio Adrian. Hospital Italiano; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina | |
| dc.format | application/pdf | es |
| dc.identifier.citation | Dell'era, Silvina; Gimeno Santos, Elena; Fiad Chain, Nahir Ayleen; Castellano Barneche, María Florencia; Macario Turón, Gonzalo; et al.; Exactitud del Xiaomi Mi Band 4 para contabilizar pasos en adultos con enfermedades respiratorias crónicas: Estudio de concordancia; Asociación Latinoamericana de Tórax; Respirar; 16; 2; 6-2024; 1-12 | es |
| dc.identifier.institucional | CONICET | |
| dc.identifier.issn | 2953-3414 | es |
| dc.identifier.repo | CONICET Digital | |
| dc.identifier.uri | http://hdl.handle.net/11336/243621 | |
| dc.journal.ciudad | Buenos Aires | es |
| dc.journal.number | 2 | es |
| dc.journal.pagination | 1-12 | es |
| dc.journal.pais | Argentina | es |
| dc.journal.title | Respirar | es |
| dc.journal.volume | 16 | es |
| dc.language.iso | spa | es |
| dc.publisher | Asociación Latinoamericana de Tórax | es |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/url/https://respirar.alatorax.org/index.php/respirar/article/view/207 | |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.55720/respirar.16.2.1 | |
| dc.rights | info:eu-repo/semantics/openAccess | * |
| dc.rights.uri | https://creativecommons.org/licenses/by/2.5/ar/ | * |
| dc.subject | EJERCICIO | es |
| dc.subject | RASTREADORES DE ACTIVIDAD FÍSICA | es |
| dc.subject | DISPOSITIVOS ELECTRÓNICOS PORTÁTILES | es |
| dc.subject | ENFERMEDAD PULMONAR OBSTRUCTIVA CRÓNICA | es |
| dc.subject.classification | Sistema Respiratorio | es |
| dc.subject.classification | Medicina Clínica | es |
| dc.subject.classification | CIENCIAS MÉDICAS Y DE LA SALUD | es |
| dc.title | Exactitud del Xiaomi Mi Band 4 para contabilizar pasos en adultos con enfermedades respiratorias crónicas: Estudio de concordancia | es |
| dc.title | Accuracy of the Xiaomi Mi Band 4 for Steps Counting in Adults with Chronic Respiratory Diseases: Agreement Study | es |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:ar-repo/semantics/artículo | |
| dc.type | info:eu-repo/semantics/publishedVersion | |
Archivos
Bloque original
Cargando...
- Nombre:
- CONICET_Digital_Nro.a758e91e-0841-4de8-b103-4156f46f633a_B.pdf
- Tamaño:
- 771.07 KB
- Formato:
- Adobe Portable Document Format