Evento

Analysis of pelvic lymph node margin using prostate fiducial markers, for SBRT treatments

Torres Díaz, Jorge Icon; Castro Peña, Pablo ; Garrigó, Edgardo ; Venencia, Daniel

Otros responsables

Fecha

2019

Editorial

Wiley

Revista

Título del libro

Nombre del evento

American Association of Physicists in Medicine 58th Annual Meeting and Exhibition

Fecha del evento

2016-07

Institución organizadora

American Association of Physicists in Medicine

ISSN

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Congreso

Palabras clave

Resumen

Purpose: The use of fiducials markers in prostate treatment allows a precise localization of this volume. Typical prostate SBRT margins with fiducials markers are 5mm in all directions, except toward the rectum, where 3mm is used. For some patients nearby pelvic lymph nodes with 5mm margin need to be irradiate assuming that its localization is linked to the prostate fiducial markers instead of bony anatomy. The purpose of this work was to analyze the geometric impact of locate the lymph node regions through the patient positioning by prostate fiducial markers. Methods: 10 patients with prostate cancer with lymph nodes indication were selected. Each patient had 5 implanted titanium fiducial markers....

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa