Artículo

Extending neutron autoradiography technique for boron concentration measurements in hard tissues

Provenzano, Lucas Icon; Olivera, María Silvina ; Saint Martin, María Laura Gisela ; Rodriguez, Luis Miguel Icon; Fregenal, Daniel Eduardo Icon; Thorp, Silvia Inés ; Pozzi, Emiliano César Cayetano ; Curotto, Paula Icon; Postuma, Ian ; Altieri, Saverio ; González, Sara Josefina Icon; Bortolussi, Silva ; Portu, Agustina Mariana Icon

Otros responsables

Fecha

07/2018

Editorial

Pergamon-Elsevier Science Ltd

Revista

Applied Radiation and Isotopes

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0969-8043

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

The neutron autoradiography technique using polycarbonate nuclear track detectors (NTD) has been extended to quantify the boron concentration in hard tissues, an application of special interest in Boron Neutron Capture Therapy (BNCT). Chemical and mechanical processing methods to prepare thin tissue sections as required by this technique have been explored. Four different decalcification methods governed by slow and fast kinetics were tested in boron-loaded bones. Due to the significant loss of the boron content, this technique was discarded. On the contrary, mechanical manipulation to obtain bone powder and tissue sections of tens of microns thick proved reproducible and suitable, ensuring a proper conservation of the boron content in the samples. A calibration curve that relates the 10B concentration of a bone sample and the track density in a Lexan NTD is presented. Bone powder embedded in boric acid solution with known boron concentrations between 0 and 100 ppm was used as a standard material. The samples, contained in slim Lexan cases, were exposed to a neutron fluence of 1012 cm−2 at the thermal column central facility of the RA-3 reactor (Argentina). The revealed tracks in the NTD were counted with an image processing software. The effect of track overlapping was studied and corresponding corrections were implemented in the presented calibration curve. Stochastic simulations of the track densities produced by the products of the 10B thermal neutron capture reaction for different boron concentrations in bone were performed and compared with the experimental results. The remarkable agreement between the two curves suggested the suitability of the obtained experimental calibration curve. This neutron autoradiography technique was finally applied to determine the boron concentration in pulverized and compact bone samples coming from a sheep experimental model. The obtained results for both type of samples agreed with boron measurements carried out by ICP-OES within experimental uncertainties. The fact that the histological structure of bone sections remains preserved allows for future boron microdistribution analysis.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd