Artículo

The Role of Hemodynamics in Intracranial Bifurcation Arteries after Aneurysm Treatment with Flow-Diverter Stents

Narata, A. P. ; De Moura, F. S. ; Larrabide, Ignacio Icon; Perrault, C. M. ; Patat, F. ; Bibi, R. ; Velasco, S. ; Januel, A. C. ; Cognard, C. ; Chapot, R. ; Bouakaz, A. ; Sennoga, C. A. ; Marzo, A.

Otros responsables

Fecha

02/2018

Editorial

American Society of Neuroradiology

Revista

American Journal Of Neuroradiology

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0195-6108

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

BACKGROUND AND PURPOSE: Treatment of intracranial bifurcation aneurysms with flow-diverter stents can lead to caliber changes of the distal vessels in a subacute phase. This study aims to evaluate whether local anatomy and flow disruption induced by flow-diverter stents are associated with vessel caliber changes in intracranial bifurcations. MATERIALS AND METHODS: Radiologic images and demographic data were acquired for 25 patients with bifurcation aneurysms treated with flow-diverter stents. Whisker plots and Mann-Whitney rank sum tests were used to evaluate if anatomic data and caliber changes could be linked. Symmetry/asymmetry were defined as diameter ratio 1 symmetric and diameter ratio 1 asymmetric. Computational fluid dynamics was performed on idealized and patient-specific anatomies to evaluate flow changes induced by flow-diverter stents in the jailed vessel. RESULTS: Statistical analysis identified a marked correspondence between asymmetric bifurcation and caliber change. Symmetry ratios were lower for cases showing narrowing or subacute occlusion (medium daughter vessel diameter ratio 0.59) compared with cases with posttreatment caliber conservation (medium daughter vessel diameter ratio 0.95). Computational fluid dynamics analysis in idealized and patient-specific anatomies showed that wall shear stress in the jailed vessel was more affected when flow-diverter stents were deployed in asymmetric bifurcations (diameter ratio 0.65) and less affected when deployed in symmetric anatomies (diameter ratio 1.00). CONCLUSIONS: Anatomic data analysis showed statistically significant correspondence between caliber changes and bifurcation asymmetry characterized by diameter ratio 0.7 (P .001). Similarly, computational fluid dynamics results showed the highest impact on hemodynamics when flow-diverter stents are deployed in asymmetric bifurcations (diameter ratio 0.65) with noticeable changes on wall sheer stress fields. Further research and clinical validation are necessary to identify all elements involved in vessel caliber changes after flow-diverter stent procedures.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa