Evaluación del confort higrotérmico invernal en viviendas unifamiliares del gran La Plata mediante auditorías
; Gomez, Analia Fernanda
; Vagge, Carolina Soledad
; Salvetti, Maria Belen
; Marsilese, Mariela Ines ; Diulio, María de la Paz
; Garcia Santa Cruz, Mauro Gabriel 
Otros responsables
Fecha
09/2012
Editorial
Asociación Argentina de Energía Solar
Revista
Avances en Energías Renovables y Medio Ambiente
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0329-5184
eISSN
ISBN
Idioma
Español
Tipo del evento
Clasificación temática
Palabras clave
Resumen
El trabajo presenta resultados de la campaña de auditorías de invierno en viviendas unifamiliares de producción privada en el gran La Plata, con el objetivo de analizar comparativamente el confort higrotérmico de estas. Se utilizan microadquisidores de datos HOBO y el protocolo de mediciones del LAyHS. Se discuten las variaciones de confort por zonas de la vivienda junto al nivel de confort higrotérmico relativo que alcanzan en función del tipo y nivel de calefacción. Se encuentra que a pesar de estar calefaccionadas las viviendas no se encuentran en confort higrotérmico la mayor parte de hs de medición siendo los niveles más bajos en el sector de uso nocturno.
The paper presents results of the winter campaign audits in private production houses in the greater La Plata, in order to analyze comparatively the hygrothermal comfort of these. Where used Microadquisidores HOBO data and protocol LAyHS measurements. Variations are discussed comfort for housing areas along hygrothermal comfort level reaching depending on the type and level of heating. It is found that despite being heated housing are not in hygrothermal comfort most of measurement hours being the lowest levels in the field of night use.
The paper presents results of the winter campaign audits in private production houses in the greater La Plata, in order to analyze comparatively the hygrothermal comfort of these. Where used Microadquisidores HOBO data and protocol LAyHS measurements. Variations are discussed comfort for housing areas along hygrothermal comfort level reaching depending on the type and level of heating. It is found that despite being heated housing are not in hygrothermal comfort most of measurement hours being the lowest levels in the field of night use.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa