Artículo

Energy reconstruction of hadron-initiated showers of ultra-high energy cosmic rays

Ros, G. ; Medina Tanco, Gustavo Adolfo ; Supanitsky, Alberto Daniel Icon; del Peral, L. ; Rodríguez Frías, M. D.

Otros responsables

Fecha

04/2015

Editorial

Elsevier Science

Revista

Astroparticle Physics

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0927-6505

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

The current methods to determine the primary energy of ultra-high energy cosmic rays (UHECRs) are different when dealing with hadron or photon primaries. The current experiments combine two different techniques, an array of surface detectors and fluorescence telescopes. The latter allow an almost calorimetric measurement of the primary energy. Thus, hadron-initiated showers detected by both type of detectors are used to calibrate the energy estimator from the surface array (usually the interpolated signal at a certain distance from the shower core S(r_0) with the primary energy. On the other hand, this calibration is not feasible when searching for photon primaries since no high energy photon has been unambiguously detected so far. Therefore, pure Monte Carlo parametrizations are used instead. In this work, we present a new method to determine the primary energy of hadron-induced showers in a hybrid experiment based on a technique previously developed for photon primaries. It consists on a set of calibration curves that relate the surface energy estimator, S(r_0), and the depth of maximum development of the shower, Xmax, obtained from the fluorescence telescopes. Then, the primary energy can be determined from pure surface information since S(r_0) and the zenith angle of the incoming shower are only needed. Considering a mixed sample of ultra-high energy proton and iron primaries and taking into account the reconstruction uncertainties and shower to shower fluctuations, we demonstrate that the primary energy may be determined with a systematic uncertainty below 1% and resolution around16% in the energy range from 10^18.5 to 10^19.6 eV. Several array geometries, the shape of the energy error distributions and the uncertainties due to the unknown composition of the primary flux have been analyzed as well.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd