Simulación solar y monitoreo del edificio ampliación oeste de la Facultad de Arquitectura, Urbanismo y Diseño de la Universidad Nacional de Córdoba
; Avalos Ambroggio, Ana Sofia
; Gatani, Mariana Pilar 
Otros responsables
Fecha
02/2018
Editorial
Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño
Revista
C&T Des Res Architettura
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
2525-1147
eISSN
ISBN
Idioma
Español
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Este trabajo comprende la primera etapa de la evaluación del desempeño térmico energético del edificio ampliación, ala oeste, de la Facultad de Arquitectura de la Universidad Nacional de Córdoba y constituye un avance de la investigación "Evaluación energética de edificios institucionales. Simulaciones, monitoreo y cálculo de cargas térmicas, demandas y consumos". Consiste en la simulación con el programa Ecotect Analysis del comportamiento del edificio frente al sol, estudios cualitativos y cuantitativos de sombras y obstrucciones, donde se obtuvieron datos de exposición solar, acceso e incidencia solar y máscaras de sombras de las aberturas. Se realizó además el monitoreo de las temperaturas interiores y exteriores y humedad relativa utilizando Hobos Data Logger ubicados en puntos estratégicos del edificio, durante los meses representativos de solsticios y equinoccios, para relevar las condiciones interiores de temperatura. Se compararon los resultados de la simulación con los de monitoreo para obtener conclusiones y evaluar el desempeño del edificio, de sus aberturas y sus protecciones. El análisis del monitoreo del espacio interior arrojó curvas de temperaturas superiores a las exteriores durante todo el año, dando cuenta de espacios muy calurosos en las estaciones verano y primavera. En los resultados alcanzados, se observó que las curvas interiores copian la trayectoria de la curva exterior de temperatura, con muy poco retardo térmico y amortiguación.
This work includes the first stage of the evaluation of the thermal energy performance of the building, west wing, of the Faculty of Architecture of the National University of Cordoba and constitutes an advance of the research "Energy evaluation of institutional buildings. Simulations, monitoring and calculation of thermal loads, demands and consumption ". It consists of the simulation with the program Ecotect Analysis of the behavior of the building in front of the sun, qualitative and quantitative studies of shadows and obstructions, where data of solar exposure, access and solar incidence were obtained and shade masks of the openings. Monitoring of indoor and outdoor temperatures and relative humidity were also performed using the Hobos Data Logger located at strategic points of the building, during the representative months of solstices and equinoxes, to relieve the internal temperature conditions. The results of the simulation and the monitoring were compared to obtain conclusions and evaluate the performance of the building, its openings and its protections. The analysis of the interior space monitoring yielded higher temperature curves than the exteriors throughout the year, giving account of very hot spaces in the summer and spring seasons. In the results obtained, it was observed that the interior curves copied the trajectory of the external curve of temperature, with very little thermal delay and damping.
This work includes the first stage of the evaluation of the thermal energy performance of the building, west wing, of the Faculty of Architecture of the National University of Cordoba and constitutes an advance of the research "Energy evaluation of institutional buildings. Simulations, monitoring and calculation of thermal loads, demands and consumption ". It consists of the simulation with the program Ecotect Analysis of the behavior of the building in front of the sun, qualitative and quantitative studies of shadows and obstructions, where data of solar exposure, access and solar incidence were obtained and shade masks of the openings. Monitoring of indoor and outdoor temperatures and relative humidity were also performed using the Hobos Data Logger located at strategic points of the building, during the representative months of solstices and equinoxes, to relieve the internal temperature conditions. The results of the simulation and the monitoring were compared to obtain conclusions and evaluate the performance of the building, its openings and its protections. The analysis of the interior space monitoring yielded higher temperature curves than the exteriors throughout the year, giving account of very hot spaces in the summer and spring seasons. In the results obtained, it was observed that the interior curves copied the trajectory of the external curve of temperature, with very little thermal delay and damping.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-sa