Holdup models from experimental conductance data in a bubble column | ||
| dc.conicet.organizacion | Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones para la Industria Química. Universidad Nacional de Salta. Facultad de Ingeniería. Instituto de Investigaciones para la Industria Química | |
| dc.conicet.organizacion | Universidad Nacional de Salta. Facultad de Ingeniería | |
| dc.contributor.author | Mattenella, Lilian Ester | |
| dc.contributor.author | Zapiola, C. R. | |
| dc.date.issued | 2001-02 | |
| dc.description.abstract | Mathematical models for the calculation of gas holdup in liquid-gas systems from experimental measures of the electrical conductance at several frother levels are presented in this paper. Experimental data were taken by a computer connected to conductance electrodes fixed in an acrylic transparent pilot flotation column. In the first stage of data analysis a relationship between the relative conductance and gas holdup on constant frother concentration was established. In the second stage, variable frother concentration was introduced. Finally, a relationship between the relative conductance, the gas holdup and the interaction between gas holdup and the square root of frother concentration was determined. | es |
| dc.description.fil | Fil: Mattenella, Lilian Ester. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Salta. Instituto de Investigaciones para la Industria Química. Universidad Nacional de Salta. Facultad de Ingeniería. Instituto de Investigaciones para la Industria Química; Argentina | |
| dc.description.fil | Fil: Zapiola, C. R.. Universidad Nacional de Salta. Facultad de Ingeniería; Argentina | |
| dc.format | application/pdf | es |
| dc.identifier.citation | Mattenella, Lilian Ester; Zapiola, C. R.; Holdup models from experimental conductance data in a bubble column; Pergamon-Elsevier Science Ltd; Minerals Engineering; 14; 2; 2-2001; 257-262 | es |
| dc.identifier.institucional | CONICET | |
| dc.identifier.issn | 0892-6875 | es |
| dc.identifier.repo | CONICET Digital | |
| dc.identifier.uri | http://hdl.handle.net/11336/70797 | |
| dc.journal.number | 2 | es |
| dc.journal.pagination | 257-262 | es |
| dc.journal.pais | Estados Unidos | es |
| dc.journal.title | Minerals Engineering | es |
| dc.journal.volume | 14 | es |
| dc.language.iso | eng | es |
| dc.publisher | Pergamon-Elsevier Science Ltd | es |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/S0892-6875(00)00180-1 | |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0892687500001801 | |
| dc.rights | info:eu-repo/semantics/openAccess | * |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.5/ar/ | * |
| dc.subject | Control de Procesos | es |
| dc.subject | Modelo | es |
| dc.subject | Flotacion por Espuma | es |
| dc.subject | Flotacion Columnar | es |
| dc.subject.classification | Otras Ingeniería Química | es |
| dc.subject.classification | Ingeniería Química | es |
| dc.subject.classification | INGENIERÍAS Y TECNOLOGÍAS | es |
| dc.title | Holdup models from experimental conductance data in a bubble column | es |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:ar-repo/semantics/artículo | |
| dc.type | info:eu-repo/semantics/publishedVersion | |
Archivos
Bloque original
Cargando...
- Nombre:
- CONICET_Digital_Nro.988aeef2-fea1-49b8-9653-d297b719ef51_B.pdf
- Tamaño:
- 280.32 KB
- Formato:
- Adobe Portable Document Format
- Descripción: