Artículo

Multi-walled carbon nanotubes functionalized with a new Schiff base containing phenylboronic acid residues: application to the development of a bienzymatic glucose biosensor using a response surface methodology approach

Tamborelli, Luis Alejandro Icon; Vaschetti, Virginia María Icon; Viada, Benjamín Nahuel Icon; López Mujica, Michael Earvin Jose Icon; Bollo, Soledad ; Venegas Yazigi, Diego ; Hermosilla Ibáñez, Patricio ; Rivas, Gustavo Adolfo Icon; Dalmasso, Pablo Roberto Icon

Otros responsables

Fecha

08/2024

Editorial

Springer Wien

Revista

Mikrochimica Acta

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0026-3672

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

An innovative supramolecular architecture is reported for bienzymatic glucose biosensing based on the use of a nanohybrid made of multi-walled carbon nanotubes (MWCNTs) non-covalently functionalized with a Schiff base modified with two phenylboronic acid residues (SB-dBA) as platform for the site-specific immobilization of the glycoproteins glucose oxidase (GOx) and horseradish peroxidase (HRP). The analytical signal was obtained from amperometric experiments at − 0.050 V in the presence of 5.0 × 10−4 M hydroquinone as redox mediator. The concentration of GOx and HRP and the interaction time between the enzymes and the nanohybrid MWCNT–SB-dBA deposited at glassy carbon electrodes (GCEs) were optimized through a central composite design (CCD)/response surface methodology (RSM). The optimal concentrations of GOx and HRP were 3.0 mg mL−1 and 1.50 mg mL−1, respectively, while the optimum interaction time was 3.0 min. The bienzymatic biosensor presented a sensitivity of (24 ± 2) × 102 μA dL mg−1 ((44 ± 4) × 102 μA M−1), a linear range between 0.06 mg dL−1 and 21.6 mg dL−1 (3.1 μM–1.2 mM) (R2 = 0.9991), and detection and quantification limits of 0.02 mg dL−1 (1.0 μM) and 0.06 mg dL−1 (3.1 μM), respectively. The reproducibility for five sensors prepared with the same MWCNT–SB-dBA nanohybrid was 6.3%, while the reproducibility for sensors prepared with five different nanohybrids and five electrodes each was 7.9%. The GCE/MWCNT–SB-dBA/GOx-HRP was successfully used for the quantification of glucose in artificial human urine and commercial human serum samples.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa