Low cost monitoring system for safe production of hydrogen from bio-ethanol
; Zumoffen, David Alejandro Ramon
; Basualdo, Marta Susana Otros responsables
Fecha
2013-10-25
Editorial
Elsevier
Revista
International Journal of Hydrogen Energy
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0360-3199
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Resumen
In this paper a monitoring system is developed to guarantee safety operational conditions for the hydrogen production from bioethanol. The key idea is to detect the most critical faults with the minimum number of sensors. It can be done through a fault detectability index (FDI) which drives to the optimal measurements selection for building a proper monitoring system. The FDI calculation is based on principal component analysis (PCA) model with combined statistics. It takes into account those sensors already selected for control purposes and penalizes the use of new measurement devices. The overall methodology is tested for fifteen failures such as the catalyzer deterioration in the reforming reactor, faults at the fuel cell, sensors and actuators. Hence, the investment cost can be reduced drastically without losing quality of fault detection. The monitoring system with the selected sensors by the FDI performs better than using all the available plant measurements.