Diagnóstico de virus respiratorios utilizando un sistema automatizado de PCR múltiples (FilmArray) y su comparación con métodos convencionales
; Carballal, Guadalupe
; Ricarte, Joaquina Carmen
; Echavarría, Marcela Silvia 
Otros responsables
Fecha
01/2015
Editorial
Asociación Argentina de Microbiología
Revista
Revista Argentina de Microbiología
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0325-7541
eISSN
1851-7617
ISBN
Idioma
Español
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Las infecciones respiratorias agudas producen una importante morbimortalidad y comúnmente son causadas por virus. En Argentina, los programas de vigilancia epidemiológica se basan en la detección de antígenos virales por inmunofluorescencia (IF), aunque es bien conocido que los métodos moleculares son más sensibles. El panel respiratorio (PR) FilmArray (PR-FilmArray) es un equipo comercial automatizado de PCR múltiples que detecta 17 virus respiratorios y 3 bacterias, en un sistema cerrado que requiere 5 min de procesamiento y una 1 h de instrumentación. Se evaluó un total de 315 muestras respiratorias de niños menores de 6 años con infecciones respiratorias agudas por IF para 8 virus respiratorios y por RT-PCR para rinovirus. Posteriormente, estas muestras se estudiaron con el PR-FilmArray. La frecuencia de positividad al considerar los 9 virus estudiados por IF y RT-PCR fue del 75 %; por PR-FilmArray fue del 92 %. El porcentaje de acuerdo positivo entre ambas metodologías fue del 70,5 % y el de acuerdo negativo fue del 99,6 % (intervalo de confianza 95 %: 65,5-75,1 y 99,2-99,8, respectivamente). El PR-FilmArray permitió obtener un mayor diagnóstico positivo (97 %) y detectó otros virus, como los coronavirus NL63, 229E, OC43 y HKU1 (10 %) y los bocavirus (18 %). Además, permitió identificar coinfecciones múltiples (39 %) con 2, 3, 4 y hasta 5 virus. Actualmente, la IF continúa siendo el método más utilizado en los países latinoamericanos para el diagnóstico de virus respiratorios por su bajo costo, por su capacidad para procesar un alto número de muestras simultáneamente y porque los resultados de los virus más frecuentes están disponibles en 5 h. Sin embargo, la futura incorporación de métodos moleculares aumentaría notablemente la capacidad diagnóstica.
Acute respiratory infections, which are commonly caused by viruses, are an important cause of morbidity and mortality in children. In Argentina, national surveillance programs for the detection of respiratory viruses are usually performed by using immunofluorescence (IF) assays, although it is well known that molecular methods are more sensitive. An automated multiplex PCR device, the FilmArray-Respiratory Panel (FilmArray-RP), can detect 17 viral and 3 bacterial pathogens in a closed system that requires only 5 min of hands-on time and 1 h of instrumentation time. A total of 315 respiratory samples from children under 6 years of age suffering from acute respiratory infections, were studied by IF for 8 respiratory viruses and by RT-PCR for rhinoviruses. Later, these samples were tested by the FilmArray-RP. The positivity frequency obtained for the 9 viruses tested was 75% by IF/RT-PCR and 92% by the FilmArray-RP. The positive and negative percent agreement between both methods was 70.5%whereas the negative percent agreement was 99.6% (95% confidence interval:65.5-75.1 and 99.2-99.8 respectively). The FilmArray-RP allowed a higher positive diagnosis (97%) and detected other viruses such as corona virus NL63, 229E, OC43, HKU1 (10%) and bocavirus (18%). In addition, this method identified multiple coinfections (39%) with 2, 3, 4 and up to 5 different viruses. At present, IF is still the most frequently used method in most Latin American countries for respiratory viruses diagnosis due to its low cost, its capability to process a high number of samples simultaneously and the fast determination of results for the most frequent viruses, which are available within 5 h. However, the coming incorporation of molecular methods in routine procedures will significantly increase the diagnostic yield of these infections.
Acute respiratory infections, which are commonly caused by viruses, are an important cause of morbidity and mortality in children. In Argentina, national surveillance programs for the detection of respiratory viruses are usually performed by using immunofluorescence (IF) assays, although it is well known that molecular methods are more sensitive. An automated multiplex PCR device, the FilmArray-Respiratory Panel (FilmArray-RP), can detect 17 viral and 3 bacterial pathogens in a closed system that requires only 5 min of hands-on time and 1 h of instrumentation time. A total of 315 respiratory samples from children under 6 years of age suffering from acute respiratory infections, were studied by IF for 8 respiratory viruses and by RT-PCR for rhinoviruses. Later, these samples were tested by the FilmArray-RP. The positivity frequency obtained for the 9 viruses tested was 75% by IF/RT-PCR and 92% by the FilmArray-RP. The positive and negative percent agreement between both methods was 70.5%whereas the negative percent agreement was 99.6% (95% confidence interval:65.5-75.1 and 99.2-99.8 respectively). The FilmArray-RP allowed a higher positive diagnosis (97%) and detected other viruses such as corona virus NL63, 229E, OC43, HKU1 (10%) and bocavirus (18%). In addition, this method identified multiple coinfections (39%) with 2, 3, 4 and up to 5 different viruses. At present, IF is still the most frequently used method in most Latin American countries for respiratory viruses diagnosis due to its low cost, its capability to process a high number of samples simultaneously and the fast determination of results for the most frequent viruses, which are available within 5 h. However, the coming incorporation of molecular methods in routine procedures will significantly increase the diagnostic yield of these infections.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-nd
