Optimizing Diagnostic Accuracy of Fine Needle Aspiration Biopsy Calcitonin Measurements in Detecting Medullary Thyroid Carcinoma
; Brenzoni, Pablo ; Lencioni, Melisa ; Jaroslavsky, Maria Jose ; Spengler, Eunice ; Voogd, Ana ; Firpo, Claudia ; Saco, Pedro ; Piñero, Federico ; Negueruela, Maria Otros responsables
Fecha
02/2024
Editorial
Mary Ann Liebert
Revista
Thyroid
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
1050-7256
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
electrochemiluminescence immunoassay (ECLIA) obtained from the washout fluid of fine needle aspiration (FNA-Ctn) for the diagnosis of medullary thyroid carcinoma (MTC) is currently not established. We evaluated the diagnostic accuracy and clinical utility of FNA-Ctn for the diagnosis and location of MTC in patients with nodular or multinodular goiters. Methods: This was a case-control study nested on a prospective multicenter cohort of patients with nodular or multinodular goiter, normal or elevated serum Ctn, and thyroidectomy indications. Ctn and FNA-Ctn were measured using ECLIA methodology before surgery. From this nested cohort, MTC cases and controls (non-medullary pathology) were identified from the final pathological analysis. Cumulative incidence sampling of controls was randomly performed at a ratio of 1:2. Sensitivity, specificity, and area under the receiver operator curve (AUROC) were calculated for patients and the total number of thyroid nodules. Results: From 1272 patients included in the prospective cohort, 50 MTC cases and 105 controls were included. In this study, 286 thyroid nodules were evaluated (63 MTC and 223 non-MTCs). The median serum Ctn value was significantly higher in cases (525 pg/mL [interquartile range (IQR), 162.5-1.200]) than in controls (1.6 pg/mL [IQR, 0.5-5.6]; p < 0.001). The median FNA-Ctn value was significantly higher in MTC nodules (3.100 pg/mL [IQR, 450-45,200]) than in non-MTC nodules (0.5 pg/mL [IQR, 0.5-0.5]; p < 0.0001). In 11 MTC patients with multinodular goiter, the FNA-Ctn value was significantly higher in non-medullary nodules located in the same lobe where an MTC nodule was diagnosed (p = 0.0002). Overall, the FNA-Ctn AUROC was 0.99 [95% confidence interval, 0.98-1.0], and a threshold of ≥220 pg/mL showed 100% sensitivity and 98% specificity for MTC diagnosis. Conclusions: The use of FNA-Ctn measured by ECLIA showed adequate diagnostic accuracy for MTC diagnosis. Moreover, it may be clinically useful for localization in multinodular goiter when lobectomy is considered.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa
