Artículo

Optimizing Diagnostic Accuracy of Fine Needle Aspiration Biopsy Calcitonin Measurements in Detecting Medullary Thyroid Carcinoma

Cavallo, Andrea Camila ; Pitoia, Fabián ; Roberti, Javier Eugenio Icon; Brenzoni, Pablo ; Lencioni, Melisa ; Jaroslavsky, Maria Jose ; Spengler, Eunice ; Voogd, Ana ; Firpo, Claudia ; Saco, Pedro ; Piñero, Federico ; Negueruela, Maria

Otros responsables

Fecha

02/2024

Editorial

Mary Ann Liebert

Revista

Thyroid

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1050-7256

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

electrochemiluminescence immunoassay (ECLIA) obtained from the washout fluid of fine needle aspiration (FNA-Ctn) for the diagnosis of medullary thyroid carcinoma (MTC) is currently not established. We evaluated the diagnostic accuracy and clinical utility of FNA-Ctn for the diagnosis and location of MTC in patients with nodular or multinodular goiters. Methods: This was a case-control study nested on a prospective multicenter cohort of patients with nodular or multinodular goiter, normal or elevated serum Ctn, and thyroidectomy indications. Ctn and FNA-Ctn were measured using ECLIA methodology before surgery. From this nested cohort, MTC cases and controls (non-medullary pathology) were identified from the final pathological analysis. Cumulative incidence sampling of controls was randomly performed at a ratio of 1:2. Sensitivity, specificity, and area under the receiver operator curve (AUROC) were calculated for patients and the total number of thyroid nodules. Results: From 1272 patients included in the prospective cohort, 50 MTC cases and 105 controls were included. In this study, 286 thyroid nodules were evaluated (63 MTC and 223 non-MTCs). The median serum Ctn value was significantly higher in cases (525 pg/mL [interquartile range (IQR), 162.5-1.200]) than in controls (1.6 pg/mL [IQR, 0.5-5.6]; p < 0.001). The median FNA-Ctn value was significantly higher in MTC nodules (3.100 pg/mL [IQR, 450-45,200]) than in non-MTC nodules (0.5 pg/mL [IQR, 0.5-0.5]; p < 0.0001). In 11 MTC patients with multinodular goiter, the FNA-Ctn value was significantly higher in non-medullary nodules located in the same lobe where an MTC nodule was diagnosed (p = 0.0002). Overall, the FNA-Ctn AUROC was 0.99 [95% confidence interval, 0.98-1.0], and a threshold of ≥220 pg/mL showed 100% sensitivity and 98% specificity for MTC diagnosis. Conclusions: The use of FNA-Ctn measured by ECLIA showed adequate diagnostic accuracy for MTC diagnosis. Moreover, it may be clinically useful for localization in multinodular goiter when lobectomy is considered.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa