Artículo

Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study

Tusman, Gerardo Horacio ; Acosta, Cecilia María ; Pulletz, Sven ; Böhm, Stephan H. ; Scandurra, Adriana Gabriela ; Martinez Arca, Jorge Icon; Madorno, Matias ; Suárez Sipmann, Fernando

Otros responsables

Fecha

2019-10-15

Editorial

Springer Netherlands

Revista

Journal of Clinical Monitoring and Computing

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1387-1307

eISSN

1573-2614

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

To determine whether a classification based on the contour of the photoplethysmography signal (PPGc) can detect changes in systolic arterial blood pressure (SAP) and vascular tone. Episodes of normotension (SAP 90–140 mmHg), hypertension (SAP > 140 mmHg) and hypotension (SAP < 90 mmHg) were analyzed in 15 cardiac surgery patients. SAP and two surrogates of the vascular tone, systemic vascular resistance (SVR) and vascular compliance (Cvasc = stroke volume/pulse pressure) were compared with PPGc. Changes in PPG amplitude (foot-to-peak distance) and dicrotic notch position were used to define 6 classes taking class III as a normal vascular tone with a notch placed between 20 and 50% of the PPG amplitude. Class I-to-II represented vasoconstriction with notch placed > 50% in a small PPG, while class IV-to-VI described vasodilation with a notch placed < 20% in a tall PPG wave. 190 datasets were analyzed including 61 episodes of hypertension [SAP = 159 (151–170) mmHg (median 1st–3rd quartiles)], 84 of normotension, SAP = 124 (113–131) mmHg and 45 of hypotension SAP = 85(80–87) mmHg. SAP were well correlated with SVR (r = 0.78, p < 0.0001) and Cvasc (r = 0.84, p < 0.0001). The PPG-based classification correlated well with SAP (r = − 0.90, p < 0.0001), SVR (r = − 0.72, p < 0.0001) and Cvasc (r = 0.82, p < 0.0001). The PPGc misclassified 7 out of the 190 episodes, presenting good accuracy (98.4% and 97.8%), sensitivity (100% and 94.9%) and specificity (97.9% and 99.2%) for detecting episodes of hypotension and hypertension, respectively. Changes in arterial pressure and vascular tone were closely related to the proposed classification based on PPG waveform. Clinical Trial Registration NTC02854852.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa