Artículo

Hydrophilic interaction liquid chromatography–tandem mass spectrometry (HILIC-MS/MS) determination of cocaine and its metabolites benzoylecgonine, ecgonine methyl ester, and cocaethylene in hair samples

Quintela, Oscar ; Lendoiro, Elena ; Cruz, Angelines ; de Castro, Ana ; Quevedo, Mario Alfredo Icon; Jurado, Carmen ; López-Rivadulla, Manuel

Otros responsables

Fecha

01/2010

Editorial

Springer Heidelberg

Revista

Analytical and Bioanalytical Chemistry

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

1618-2642

eISSN

1618-2650

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

This study reports the development and validation of a method using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/ MS) for the analysis of cocaine and its metabolites benzoylecgonine (BE), ecgonine methyl ester (EME), and cocaethylene (CE) in hair samples. Decontamination was performed as follows: Firstly, the aliquot of hair was briefly rinsed with 2 mL dichloromethane, then was washed three times with 10 mL 0.01 M phosphate buffer, pH 6, for 15 min, followed by 2 mL 2-propanol for less than 2 min, and, finally, a last rinse with 2 mL dichloromethane was again done. Cocaine compounds were extracted from 10 mg of hair by incubation with 2 mL 0.1 M HCl at 50 °C for 12 h and purified by solid phase extraction with Oasis MCX cartridges. Analysis was performed by LC-MS/ MS using an Atlantis HILIC silica chromatographic column. The method was fully validated. Linearity was established over the concentration range 0.020?10.0 ng/mg for cocaine (COC), 0.010?10.0 ng/mg for BE and CE, and 0.005?2.0 ng/mg for EME, and the correlation coefficients were all >0.99. Extraction efficiency was >70% for all analytes. Limits of detection were 0.0005 ng/mg for CE and 0.001 ng/mg for the other analytes (COC, BE, and EME). Lower limits of quantification were the lowest points of the calibration curves with acceptable accuracy and precision (coefficient of variation ≤20%). Intra- and inter-day imprecision ranged between 1.5% and 9.5% and 0.7% and 12.6%, respectively. Intra- and inter-day inaccuracy ranged from 0.5% to 12.3% and from 0.7% to 7.1%, respectively. With regard to matrix effects, suppression was <27.5% in all cases. The method was applied to the analysis of several samples derived from forensic cases.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa