Wind buckling of tanks with conical roof considering shielding by another tank

Otros responsables
Fecha
06/2014
Editorial
Elsevier
Revista
Thin-Walled Structures
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0263-8231
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Oil storage tanks are usually arranged in groups in tank farms, and this configuration may affect their buckling and postbuckling strength under wind loads. The assessment of wind action on tank structures is performed in this work by means of wind tunnel experiments to evaluate the pattern of pressure distribution for a tank which is shielded by another tank under various configurations and separation between them. The experimental results show significant changes in pressures due to shielding effects. In a second stage the structural response under the pressures previously evaluated is performed by finite element analysis using both linear bifurcation and geometrically nonlinear analysis. Results of two-tank interaction are compared with those of an isolated tank. Based on the results, it is concluded that the changes in wind pressures due to group effects induce changes in buckling loads and in the associated deflected patterns.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa