QUBIC III: Laboratory characterization
; González, M. ; Almela, Daniel Alejandro
; Arnaldi, Luis Horacio ; Banfi, Cristina Silvia ; Bonaparte, Juan José ; Cobos Cerutti, Agustin Cleto
; Duca, Clara
; Etchegoyen, Alberto
; Fasciszewski Zeballos, Alejandro Miguel ; Ferreyro, Luciano Pablo
; Fracchia, Diego
; García Redondo, Manuel Elías
; Hampel, Matias Rolf
; Harari, Diego Dario
; Pastoriza, Hernan
; Platino, Manuel
; Rasztocky, Emiliano
; Salum, Juan Manuel ; Scoccola, Claudia Graciela
; Supanitsky, Alberto Daniel
; Wright, María 
Otros responsables
Fecha
2022-04-21
Editorial
IOP Publishing
Revista
Journal of Cosmology and Astroparticle Physics
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
1475-7516
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
We report on an extensive test campaign of a prototype version of the QUBIC (Q & U Bolometric Interferometer for Cosmology) instrument, carried out at Astroparticle Physics and Cosmology (APC) in Paris. Exploiting the novel concept called bolometric interferometry, QUBIC is designed to measure the CMB polarization at 150 and 220 GHz from a high altitude site at Alto Chorillo, Argentina. The prototype model called QUBIC Technological Demonstrator (QUBIC-TD) operates in a single frequency band (150 GHz) and with a reduced number of baselines, but it contains all the elements of the QUBIC instrument in its final configuration. The test campaign included measurements of the synthesized beam and of the polarization performance, as well as a verification of the interference fringe pattern. A modulated, frequency-tunable millimetre-wave source was placed in the telescope far-field and was used to simulate a point source. The QUBIC-TD field of view was scanned across the source to produce beam maps. Our measurements confirm the frequency-dependent behaviour of the beam profile, which gives QUBIC the possibility to do spectral imaging. The measured polarization performance indicates a cross-polarization leakage less than 0.6%. We also successfully tested the polarization modulation system, which is provided by a rotating half wave plate. We demonstrate the full mapmaking pipeline using data from this measurement campaign, effectively giving an end-to-end checkout of the entire QUBIC system, including all hardware subsystems, their interfaces, and the software to operate the whole system and run the analysis. Our results confirm the viability of bolometric interferometry for measurements of the CMB polarization.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa