Evento

The influence of glare generated by an LED lamp on pupillary behaviour: considerations about colour temperature

Matesanz, Beatriz M. ; Vicente, Eduardo G. ; Barrionuevo, Pablo Alejandro Icon; Arranz, Isabel

Otros responsables

Fecha

2024

Editorial

Paediatric Ophthalmology University Eye Clinic

Revista

Título del libro

Nombre del evento

27th International Colour Vision Society Meeting

Fecha del evento

2024-07-05

Institución organizadora

University Eye Clinic
International Colour Vision Society

ISSN

eISSN

ISBN

978-961-7105-42-1

Idioma

Inglés

Tipo del evento

Reunión

Clasificación temática

Resumen

The increasing adoption of LED technology in public road networks has triggered important questions regarding its impact on visual performance. Furthermore, there is a lack of information concerning the effect of glaring lamps with different Correlated colour temperatures (CCTs) on pupillary diameter dynamics This study aims to elucidate the role of CCT from commercial LED glaring lamps in the pupil light reflex.Measurements were conducted using a two-channel Maxwellian view optical system, which projected a 10º adaptation beam from a 4000K LED illuminant at three luminance levels: 0.1, 1, and 10 cd/m2. A glare of 52 lux was generated for 3 s at 10º temporal retina of the observer, using randomly selected two LED lighting sources of 2700 K and 6500 K. A CCD camera-based infrared pupilometer, integrated into the optical bench, was employed to measure pupillary diameter and eye position. Nineteen young participants, aged between 18 and 30 years, free of ocular pathologies, with refractive errors ranging between ± 6.00 D, and without alterations in colour vision, were recruited for this study.A significant effect of luminance on pupillary diameter variation was observed for both lamps with different CCTs. The maximum diameter achieved before glare onset and the minimum diameter reached during glare presentation decreased with higher background luminance levels. However, no effect of the LED lamp CCT on pupillary diameter behaviour was observed, regardless of luminance.The absence of an effect of the LED lamp CCT on pupillary diameter can be attributed to the similarity in the spectral distributions of both lamps. Consequently, CCT may not be the most suitable metric for predicting pupillary behaviour in response to glare induced by LED technology.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa