Estrategia de control droop con reducido número de sensores para inversores en paralelo en UPS
; Botterón, Fernando
; Oggier, German Gustavo
; Garcia, Guillermo 
Otros responsables
Fecha
2016
Editorial
Institute of Electrical and Electronics Engineers
Revista
Título del libro
Nombre del evento
IEEE ARGENCON 2016
Fecha del evento
2016-06-15
Institución organizadora
Universidad Tecnológica Nacional
Institute of Electrical and Electronics Engineers
Institute of Electrical and Electronics Engineers
ISSN
eISSN
ISBN
Idioma
Español
Tipo del evento
Congreso
Clasificación temática
Palabras clave
Resumen
Se propone una estrategia de control droop para la conexión de inversores monofásicos en paralelo utilizados en UPS de doble conversión. Esta estrategia logra una reducida cantidad de sensores para el ajuste de la impedancia de salida, operación con frecuencia fija de la tensión de salida, reducida corriente de circulación, excelente regulación, y cumple con las especificaciones de desempeño transitorio y de régimen permanente establecidas por normas internacionales. Se propone una metodología simple para la selección de la ganancia del controlador droop y el ajuste del valor de la impedancia de salida para cada inversor, validando la propuesta con resultados de simulación.
A droop control strategy is proposed to achieve parallel operation of single-phase inverters for double conversion UPS applications. The distinctive caracteristics of this control strategy are a reduced number of sensors to achieve output impedance adjustment, fixed frequency of the output voltage, reduced circulating current between the inverters, excelent output voltage regulation and compliance with specifications given by international standards for transient and stationary response. A simple design methodology is proposed to choose the droop controller gain and adjust the output impedance value of each inverter, validating the proposal with simulation results.
A droop control strategy is proposed to achieve parallel operation of single-phase inverters for double conversion UPS applications. The distinctive caracteristics of this control strategy are a reduced number of sensors to achieve output impedance adjustment, fixed frequency of the output voltage, reduced circulating current between the inverters, excelent output voltage regulation and compliance with specifications given by international standards for transient and stationary response. A simple design methodology is proposed to choose the droop controller gain and adjust the output impedance value of each inverter, validating the proposal with simulation results.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa