Empirical thermal comfort evaluation of single and double skin façades
; Leão, Marlon ; Leão, Érika F. T. B. Otros responsables
Fecha
04/2010
Editorial
Pergamon-Elsevier Science Ltd
Revista
Building and Environment
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
0360-1323
eISSN
ISBN
Idioma
Inglés
Tipo del evento
Clasificación temática
Palabras clave
Resumen
In this paper, the topic of thermal comfort for buildings with double skin façades and single skin façades is demonstrated and discussed. A long-term monitoring was performed in 280 office rooms distributed over 28 buildings in Germany. The survey methods were based on sensor measurements and data simultaneously gathered from questionnaire given to office users. The authors take into consideration the operative temperature, vertical gradient temperature, draught rate, radiation asymmetry, relative humidity and carbon dioxide concentration. The aim is to determine the individual sensory perception of the indoor environment and compare it to the actually measured indoor climate in buildings with double skin façades and single skin façades. In regards to the thermal comfort results, in general, it is shown that double skin façades buildings have slight advantages in relation to single skin façades buildings. © 2009 Elsevier Ltd. All rights reserved.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa