Dry-contact microelectrode membranes for wireless detection of electrical phenotypes in neonatal mouse hearts | ||
| dc.conicet.organizacion | California Institute Of Technology | |
| dc.conicet.organizacion | University of California at Los Angeles | |
| dc.conicet.organizacion | University of California at Los Angeles | |
| dc.conicet.organizacion | Northwestern Polytechnical University | |
| dc.conicet.organizacion | California Institute Of Technology | |
| dc.conicet.organizacion | Northwestern Polytechnical University | |
| dc.conicet.organizacion | Veteran Affairs Greater Los Angeles Healthcare System | |
| dc.conicet.organizacion | Consejo Nacional de Investigaciones Científicas y Técnicas | |
| dc.conicet.organizacion | Children Hospital Los Angeles | |
| dc.conicet.organizacion | California Institute Of Technology | |
| dc.conicet.organizacion | University of California at Los Angeles | |
| dc.conicet.organizacion | Veteran Affairs Greater Los Angeles Healthcare System | |
| dc.contributor.author | Zhao, Yu | |
| dc.contributor.author | Cao, Hung | |
| dc.contributor.author | Beebe, Tyler | |
| dc.contributor.author | Zhang, Hemin | |
| dc.contributor.author | Zhang, Xiaoxiao | |
| dc.contributor.author | Chang, Honglong | |
| dc.contributor.author | Scremin, Oscar Umberto | |
| dc.contributor.author | Lien, Ching Ling | |
| dc.contributor.author | Tai, Yu Chong | |
| dc.contributor.author | Hsiai, Tzung K. | |
| dc.date.issued | 2015-04 | |
| dc.description.abstract | Continuous monitoring of aberrant electrical rhythms during heart injury and repair requires prolonged data acquisition. We hereby developed a wearable microelectrode membrane that could be adherent to the chest of neonatal mice for in situ wireless recording of electrocardiogram (ECG) signals. The novel dry-contact membrane with a meshed parylene-C pad adjacent to the microelectrodes and the expandable meandrous strips allowed for varying size of the neonates. The performance was evaluated at the system level; specifically, the ECG signals (μV) acquired from the microelectrodes underwent two-stage amplification, band-pass filtering, and optical data transmission by an infrared Light Emitting Diode (LED) to the data-receiving unit. The circuitry was prototyped on a printed circuit board (PCB), consuming less than 300 μW, and was completely powered by an inductive coupling link. Distinct P waves, QRS complexes, and T waves of ECG signals were demonstrated from the non-pharmacologically sedated neonates at ~600 beats per minutes. Thus, we demonstrate the feasibility of both real-time and wireless monitoring cardiac rhythms in a neonatal mouse (17–20 mm and <1 g) via dry-contact microelectrode membrane; thus, providing a basis for diagnosing aberrant electrical conduction in animal models of cardiac injury and repair. | es |
| dc.description.fil | Fil: Zhao, Yu. California Institute Of Technology; Estados Unidos | |
| dc.description.fil | Fil: Cao, Hung. University of California at Los Angeles; Estados Unidos | |
| dc.description.fil | Fil: Beebe, Tyler. University of California at Los Angeles; Estados Unidos | |
| dc.description.fil | Fil: Zhang, Hemin. Northwestern Polytechnical University; China | |
| dc.description.fil | Fil: Zhang, Xiaoxiao. California Institute Of Technology; Estados Unidos | |
| dc.description.fil | Fil: Chang, Honglong. Northwestern Polytechnical University; China | |
| dc.description.fil | Fil: Scremin, Oscar Umberto. Veteran Affairs Greater Los Angeles Healthcare System; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina | |
| dc.description.fil | Fil: Lien, Ching Ling. Children Hospital Los Angeles; Estados Unidos | |
| dc.description.fil | Fil: Tai, Yu Chong. California Institute Of Technology; Estados Unidos | |
| dc.description.fil | Fil: Hsiai, Tzung K.. University of California at Los Angeles; Estados Unidos. Veteran Affairs Greater Los Angeles Healthcare System; Estados Unidos | |
| dc.format | application/pdf | es |
| dc.identifier.citation | Zhao, Yu; Cao, Hung; Beebe, Tyler; Zhang, Hemin; Zhang, Xiaoxiao; et al.; Dry-contact microelectrode membranes for wireless detection of electrical phenotypes in neonatal mouse hearts; Springer; Biomedical Microdevices; 17; 4-2015; 1-6 | es |
| dc.identifier.eissn | 1572-8781 | |
| dc.identifier.issn | 1387-2176 | |
| dc.identifier.uri | http://hdl.handle.net/11336/13340 | |
| dc.journal.ciudad | Nueva York | es |
| dc.journal.pagination | 1-6 | es |
| dc.journal.pais | Estados Unidos | es |
| dc.journal.title | Biomedical Microdevices | es |
| dc.journal.volume | 17 | es |
| dc.language.iso | eng | es |
| dc.publisher | Springer | es |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/ 10.1007/s10544-014-9912-y | |
| dc.relation.alternativeid | info:eu-repo/semantics/altIdentifier/url/http://link.springer.com/article/10.1007%2Fs10544-014-9912-y | |
| dc.rights | info:eu-repo/semantics/openAccess | * |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | es |
| dc.subject | Neonatal Mice | es |
| dc.subject | Wireless Monitoring | es |
| dc.subject | Dry-Contact Electrodes | es |
| dc.subject | Ecg | es |
| dc.subject | Heart Regeneration | es |
| dc.subject.classification | Biofísica | es |
| dc.subject.classification | Ciencias Biológicas | es |
| dc.subject.classification | CIENCIAS NATURALES Y EXACTAS | es |
| dc.title | Dry-contact microelectrode membranes for wireless detection of electrical phenotypes in neonatal mouse hearts | es |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:ar-repo/semantics/artículo | |
| dc.type | info:eu-repo/semantics/publishedVersion | |
Archivos
Bloque original
Cargando...
- Nombre:
- CONICET_Digital_Nro.16628.pdf
- Tamaño:
- 2.35 MB
- Formato:
- Adobe Portable Document Format