Artículo

Loop-Mediated Isothermal Amplification of Trypanosoma cruzi DNA for Point-of-Care Follow-Up of Anti-Parasitic Treatment of Chagas Disease

Muñoz Calderon, Arturo Alejandro Icon; Besuschio, Susana Alicia ; Wong, Season ; Fernández, Marisa ; García Casares, Lady Juliette Icon; Giorgio, Patricia ; Barcan, Laura A. ; Markham, Cole ; Liu, Yanwen E. ; Alarcón de Noya, Belkisyolé ; Longhi, Silvia Andrea Icon; Schijman, Alejandro Gabriel Icon

Otros responsables

Fecha

2022-04-26

Editorial

Multidisciplinary Digital Publishing Institute

Revista

Microorganisms

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

2076-2607

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

A loop-mediated isothermal amplification assay was evaluated as a surrogate marker of treatment failure in Chagas disease (CD). A convenience series of 18 acute or reactivated CD patients who received anti-parasitic treatment with benznidazole was selected—namely, nine orally infected patients: three people living with HIV and CD reactivation, five chronic CD recipients with reactivation after organ transplantation and one seronegative recipient of a kidney and liver transplant from a CD donor. Fifty-four archival samples (venous blood treated with EDTA or guanidinium hydrochloride-EDTA buffer and cerebrospinal fluid) were extracted using a Spin-column manual kit and tested by T. cruzi Loopamp kit (Tc-LAMP, index test) and standardized real-time PCR (qPCR, comparator test). Of them, 23 samples were also extracted using a novel repurposed 3D printer designed for point-of-care DNA extraction (PrintrLab). The agreement between methods was estimated by Cohen’s kappa index and Bland–Altman plot analysis. The T. cruzi Loopamp kit was as sensitive as qPCR for detecting parasite DNA in samples with parasite loads higher than 0.5 parasite equivalents/mL and infected with different discrete typing units. The agreement between qPCR and Tc-LAMP (Spin-column) or Tc-LAMP (PrintrLab) was excellent, with a mean difference of 0.02 [CI = −0.58–0.62] and −0.04 [CI = −0.45–0.37] and a Cohen’s kappa coefficient of 0.78 [CI = 0.60–0.96] and 0.90 [CI = 0.71 to 1.00], respectively. These findings encourage prospective field studies to validate the use of LAMP as a surrogate marker of treatment failure in CD.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by