Electromyography sensor for wearable multi-channel platform
; Guerrero, Federico Nicolás
; Haberman, Marcelo Alejandro
; Spinelli, Enrique Mario 
Otros responsables
Fecha
2020-06-14
Editorial
Sociedad Argentina de Bioingeniería
Revista
Revista Argentina de Bioingeniería
Título del libro
Nombre del evento
Fecha del evento
Institución organizadora
ISSN
2591-376X
eISSN
0329-5257
ISBN
Idioma
Español
Tipo del evento
Clasificación temática
Palabras clave
Resumen
Este trabajo presenta el diseño y la implementación de un sensor de EMG para un sistema de adquisición de biopotenciales multicanal vestible. El sensor propuesto incluye un circuito de referencia y driven-right-leg con componentes que limitan la corriente continua y alterna por separado para cumplir con el estándar internacional IEC 60601-1 sin dejar de lograr un alto rechazo a interferencias, considerando la cantidad de canales del sistema. Se realizaron mediciones experimentales de ganancia, rechazo de modo común y ruido, junto a un registro de electromiograma. Además, se llevaron a cabo pruebas de banco que verifican las corrientes condición de falla simple.
This paper presents the design and implementation of an EMG sensor for a wearable multi-channel biopotential acquisition system. The proposed sensor includes a reference and driven-right-leg circuit with components that limit the direct and alternating currents separately to comply with the international standard IEC 60601-1 while still achieving a high interference rejection, considering the number of channels of the system. Experimental measurements of gain, common mode rejection and noise were made, along with electromyogram recordings. In addition, bench tests were carried out that verify the limits of the currents in single-fault condition.
This paper presents the design and implementation of an EMG sensor for a wearable multi-channel biopotential acquisition system. The proposed sensor includes a reference and driven-right-leg circuit with components that limit the direct and alternating currents separately to comply with the international standard IEC 60601-1 while still achieving a high interference rejection, considering the number of channels of the system. Experimental measurements of gain, common mode rejection and noise were made, along with electromyogram recordings. In addition, bench tests were carried out that verify the limits of the currents in single-fault condition.