Artículo

Observer-Based Grid-Voltage Sensorless Synchronization and Control of a VSI-LCL Tied to an Unbalanced Grid

Fantino, Roberto Armin Icon; Busada, Claudio A. ; Solsona, Jorge Alberto Icon

Otros responsables

Fecha

07/2019

Editorial

Institute of Electrical and Electronics Engineers

Revista

Ieee Transactions On Industrial Electronics

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0278-0046

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Resumen

This paper proposes an observer-based grid-voltage sensorless strategy that allows to implement the synchronization and control of an LCL grid-tied voltage source inverter. By using exclusively the measurement of the current injected to the grid, an observer estimates both fundamental positive- and negative-sequence components of the grid voltage, with a quality (in terms of total harmonic distortion and convergence speed) comparable to that obtained with a classic double second-order generalized integrator-frequency-locked loop (DSOGI-FLL). The unmeasured LCL filter states are also estimated by the observer, and they are used to implement a full-state feedback control strategy suitable for low resonance frequency LCL filters. The effectiveness of the scheme proposed here is demonstrated by comparison with a DSOGI-FLL and with a controller recently proposed in the literature. Experimental and simulation results that demonstrate the validity and effectiveness of the proposal are presented.

Colecciones

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa