Artículo

Intra-aortic balloon pumping reduces the increased arterial load caused by acute cardiac depression, modifying central and peripheral load determinants in a time- and flow-related way

Bia, Daniel ; Cabrera Fischer, Edmundo Ignacio Icon; Zócalo, Yanina ; Armentano, Ricardo Luis

Otros responsables

Fecha

11/2011

Editorial

Springer

Revista

Heart And Vessels

Título del libro

Nombre del evento

Fecha del evento

Institución organizadora

ISSN

0910-8327

eISSN

ISBN

Idioma

Inglés

Tipo del evento

Clasificación temática

Resumen

The mechanisms that explain intra-aortic balloon pumping (IABP) effects are not completely understood, and attributing them only to pressure-associated changes in cardiac function would be an oversimplification. Since IABP modifies the aortic and systemic blood-flow pattern, flow-related effects could be expected. To characterize effects of acute heart failure (AHF) on the arterial biomechanics; IABP effects on the arterial biomechanics during AHF, and their potential time-dependence; the association between hemodynamics and biomechanical changes during AHF and IABP. Sheep (n = 6) aortic pressure, flow, and diameter were measured: (1) before (Basal) and (2) 1-3 (HF(1-3)) and 28-30 (HF(28-30)) min after starting halothane to induce AHF; and (3) at specific times (1-3, 14-15 and 28-30 min) during IABP assistance. Calculus: aortic characteristic impedance (Z(c)), beta stiffness (â), incremental (E(INC)) and pressure-strain elastic modulus (E(P)); total arterial compliance (C(G)), total systemic vascular resistance and wave propagation parameters. (1) AHF resulted in an acute increase in aortic and systemic stiffness (HF(28-30) % changes with respect to Basal conditions: â +217%, E (P) +143%, E(INC) +101%, Z(c) +52%, C(G) -13%), associated with the reduction in the aortic blood flow; (2) during AHF IABP resulted in acute beneficial changes aortic and systemic biomechanics (% changes in IABP(1-3) with respect HF(28-30): â -62%, E(P) -68%, E (INC) -66%, Z(c) -38%, C(G) 66%), and in wave propagation parameters, (3) IABP-related changes were time-dependent and associated with changes in aortic blood flow. Aortic and systemic biomechanical and impedance properties are detrimentally modified during AHF, being the changes rapidly reverted during IABP. IABP-related beneficial changes in arterial biomechanics were time-dependent and associated with IABP capability to increase blood flow.

Aprobación

Revisión

Complementado por

Referenciado por

Licencia Creative Commons

Excepto donde se indique lo contrario, la licencia de este ítem se describe como by-nc-sa